C Set Dhw Temperature; E Temperature Sensor At Bottom Of Dhw Cylinder - Viessmann VITOTRONIC 200 Service Instructions Manual

Vitotronic 200 type wo1a heat pump control unit
Table of Contents

Advertisement

600A Stop optimisation for DHW heating
Delivered condi-
tion
0

600C Set DHW temperature 2

Set temperature in the DHW cylinder
for:
■ Additional DHW heat-up function to kill
bacteria (for this a temperature sensor
must be fitted at the bottom of the
DHW cylinder; "Temperature sensor
at bottom of DHW cylinder 600E").
■ Operating status "Temp. 2" for DHW
cylinders.

600E Temperature sensor at bottom of DHW cylinder

If a second temperature sensor is instal-
led in the lower section of the DHW cyl-
inder, cylinder heating is stopped via this
sensor in operating status "Standard"
and "Temp. 2". This results in optimised
cylinder heating.
Valu
Explanation
e
"0"
Lower temperature sensor in the
DHW cylinder is not installed.
"1"
Lower temperature sensor in the
DHW cylinder is installed and
enabled.
Setting range
0 / 1
Parameter group DHW
(cont.)
Operating instructions
Delivered condi-
tion
600 (≙ 60 °C)
Delivered condi-
tion
0
Setting range
100 to 700
(≙ 10 to 70 °C)
Setting range
0 / 1
119