Viessmann VITOTRONIC 200 Service Instructions Manual page 91

Vitotronic 200 type wo1a heat pump control unit
Table of Contents

Advertisement

Diagnosis (service scans)
Diagnosis "Energy statement"
The following information can be scan-
ned:
■ "Energy statemnt heating":
Electrical energy used to operate the
heat pump and the amount of heating
energy
transferred into the heating
system.
With two stage heat pumps: "Energy
statement htg 1" and "Energy state-
ment htg 2" for heat pump stages 1
and 2.
■ "Energy statement DHW":
Electrical energy used to operate the
heat pump and the amount of energy
transferred for DHW heating
With two stage heat pumps: "Energy
statement DHW 1" and "Energy
statement DHW 2" for heat pump
stages 1 and 2.
■ "SPF heating":
Seasonal performance factor for heat-
ing.
■ "SPF DHW":
Seasonal performance factor for DHW
heating.
■ "SPF overall":
Seasonal performance factor overall.
Service menu:
1. Press OK + å simultaneously for
approx. 4 s.
2. "Diagnosis"
3. "Energy statement"
Diagnosis "Brief scan"
Following scans:
■ Temperatures
■ Software versions
■ Connected components
(cont.)
A
A Conversion factor according to the
coding card 0.1 kW, 1 kW or 10 kW
.
The energy values
ned with
"Wk." of the past year.
Note
In order to record realistic data:
Parameters "Output 5030" and "Out-
put 5130"(for heat pump stage 2) must
be set correctly.
Troubleshooting
Energy statemnt heating
Ü
kWh
è
q
Wk.
23/09
q 277 è 831
Select with
,
, can be scan-
for each calendar week
23
91

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitotronic 200 wo1a

Table of Contents