Redundancy Check On A Logical Drive; Pausing And Resuming A Redundancy Check; Stopping A Redundancy Check - G-Technology G SPEED STUDIO XL Product Manual

Hardware raid 8-bay thunderbolt 2 storage solution
Table of Contents

Advertisement

G SPEED
STUDIO
with Thunderbolt™

Redundancy Check on a Logical Drive

Redundancy Check is a routine maintenance procedure for fault-tolerant disk arrays (those with
redundancy) that ensures the redundant copies of data still match the original source data.
Redundancy Check can also correct inconsistencies.
To run Redundancy Check on a logical drive:
1. Click on the Background Activities icon. The list of background activities will appear.
2. Mouse-over Redundancy Check, then click the Start button.
3. Check the boxes to the left of the logical drives on which to run Redundancy Check.
4. Check the option you want:
• Auto Fix – Attempts to repair the problem when it finds an error
• Pause on Error – The process stops when it finds a non-repairable error
5. Click the Confirm button.

Pausing and Resuming a Redundancy Check

To pause or resume a Redundancy Check:
1. Click on the Background Activities icon. The list of background activities will appear.
2. Mouse-over Redundancy Check, then click the Pause or Resume button.

Stopping a Redundancy Check

To stop or cancel the Redundancy Check:
1. Click on the Background Activities icon. The list of background activities will appear.
2. Mouse-over Redundancy Check, then click the Stop button. Click the Confirm button.
Configuring G-SPEED Studio XL
XL
p. 87

Advertisement

Table of Contents
loading

This manual is also suitable for:

G speed studio xl with thunderbolt

Table of Contents