Lamp Change; Safety Regulations; Lamp Replacement - Elation PowerSpot 575IE User Manual

Table of Contents

Advertisement

Power Spot 575IE™
6.

Lamp Replacement

For a proper and safe lamp change, please read this chapter carefully and follow all
instructions.

6.1 Safety Regulations

• Pull out the main plug!
• Wait min. 20 minutes after the last operation to cool down the fixture.
• Don't touch the bulb of the lamp with bare fingers (this can cause damages.
• Before you put the POWER SPOT 575IE™ into operation close the casing,
otherwise your retina can be hurt!
6.2

Lamp Change

6.2.1 Be sure the unit is disconnected from it's main power supply.
6.2.2 Always allow ample time for the unit to properly cool before attempting any type of
service or repair..
6.2.3 To expose the lamp, remove the four Philips screws that secure the lamp socket
assembly to head. Carefully pull back the socket assembly.
6.2.4 Gently remove the old lamp from it's socket. If the old lamp has exploded be sure to
remove all of the old lamp fragments to prevent damage to the internal
©Elation Professionals® Los Angeles, Ca.
-