Troubleshooting
Checking and acknowledging faults
Fault code
Const.
in the dis-
play
bC
bd
bE
bF
C2
X
C5
X
78
Weat-
System
h.
character-
comp.
istics
X
Control
mode with-
out remote
control
X
Control
mode with-
out remote
control
X
Control
mode
X
Control
mode
X
Control
mode
X
Control
mode,
max. pump
speed
(cont.)
Cause
Remedy
Communication
Check con-
fault - Vitotrol
nections,
remote control
cable, coding
heating circuit A1
address A0
and the
remote con-
trol DIP
switches
Communication
fault - Vitotrol
remote control
heating circuit M2
Vitotrol remote
Check the
control incorrectly
DIP switch
encoded
settings of
the remote
control
Incorrect LON com-
Replace the
munication module
LON commu-
nication mod-
ule
Communication
Check con-
fault - solar control
nections and
unit
coding
address 54
Communication
Check coding
fault - variable
address 30
speed internal
settings;
pump
check the
heating cir-
cuit pump
DIP switch
settings.