Viessmann Vitodens 200 Service Manual page 76

8.8 to 26.0 kw gas fired wall mounted condensing boiler natural gas and lpg version
Hide thumbs Also See for Vitodens 200:
Table of Contents

Advertisement

Troubleshooting
Checking and acknowledging faults
Fault code
Const.
in the dis-
play
30
X
38
X
40
48
50
X
58
X
51
X
59
X
92
X
9A
X
93
X
9B
X
94
X
76
Weat-
System
h.
character-
comp.
istics
X
Burner
blocked
X
X
Mixer
closes
X
X
No DHW
heating
X
X
No DHW
heating
X
X
Control
mode
X
X
Control
mode
X
X
Control
mode
(cont.)
Cause
Remedy
Boiler temperature
Check the
sensor shorted out
boiler tem-
perature sen-
sor (see
page 86)
Boiler temperature
sensor lead break
Heating circuit M2
Check the
flow temperature
flow tempera-
sensor shorted out
ture sensor
Heating circuit M2
flow temperature
sensor lead break
Cylinder tempera-
Check sen-
ture sensor/comfort
sors (see
sensor/loading
page 86)
sensor shorted out
Cylinder tempera-
ture sensor/comfort
sensor/loading
sensor lead break
Cylinder tempera-
Check sen-
ture sensor 2/outlet
sors (see
sensor shorted out
page 86)
Cylinder tempera-
ture sensor 2/outlet
sensor lead break
Solar: Collector
Check sensor
temperature sensor
shorted out
Collector tempera-
ture sensor lead
break
Solar: Sensor S3
Check sensor
shorted out
Sensor S3 lead
break
Solar: Cylinder
Check sensor
temperature sensor
shorted out