Checking and acknowledging faults
Fault code
Const.
in the dis-
play
FF
X

Repairs

Checking the outside temperature sensor (weather-compen-
sated control unit)
84
Weat-
System
h.
character-
comp.
istics
X
Burner
blocked
1. Pull plug X3 from the control unit.
(cont.)
Cause
Remedy
Internal fault
Remove EMC
interference.
If the equip-
ment will not
restart, check
the boiler
coding card
and replace,
or replace the
control unit.