Coding
Code 2
(cont.)
Coding in
Function mode
the as
delivered
condition
Address:
value
65:...
Information regarding
the type of diverter
valve (not adjustable)
67:40
In conjunction with Vito-
solic solar control unit:
Set DHW value 3
6F:100
Max. output during
DHW loading 100 %,
defaulted by the boiler
coding card
71:0
*
1
DHW circulation
pump: ON according to
time program (Vito-
trol 300 enables sepa-
rate switching times)
72:0
*
1
DHW circulation
pump: ON according to
time program
73:0
*
1
DHW circulation
pump: ON according to
time program
General
76:0
Without LON communi-
cation module
*1
Only for weather-compensated control units
50
Coding
Possible change
change
Address:
value
65:0
Without diverter valve
65:1
Diverter valve by Viess-
mann
65:2
Diverter valve by Wilo
65:3
Diverter valve by Grund-
fos
67:0
DHW set value adjusta-
to
ble from 0 to 60 °C
67:60
6F:0
Max. output during DHW
to
loading adjustable from 0
6F:100
to 100 %
71:1
OFF during DHW loading
to set value 1
71:2
ON during DHW loading
to set value 1
72:1
OFF during DHW loading
to set value 2
72:2
ON during DHW loading
to set value 2
73:1
During the time program
to
1x/h ON for 5 minutes
73:6
up to 6x/h ON for 5 min-
utes
73:7
Constantly ON
76:1
With LON communication
module; automatic recog-
nition