Viessmann Vitodens 200 Service Manual page 55

8.8 to 26.0 kw gas fired wall mounted condensing boiler natural gas and lpg version
Hide thumbs Also See for Vitodens 200:
Table of Contents

Advertisement

Code 2
(cont.)
Coding in
Function mode
the as
delivered
condition
Address:
value
Boiler circuit, mixer circuit
A4:0
*
1
With frost protection
A5:5
*
1
With heating circuit
pump logic function
(economy circuit): Heat-
ing circuit pump OFF, if
the outside temperature
(AT) is 1 K higher than
the set room tempera-
ture (RT
AT > RT
Parameter address
A5:...
1
2
3
4
5
6
*1
Only for weather-compensated control units
Coding
change
Address:
value
A4:1
A5:0
A5:1
to
A5:15
)
Set
+ 1 K
Set
With heating circuit pump logic function: Heating
circuit pump OFF, if
AT > RT
+ 5 K
Set
AT > RT
+ 4 K
Set
AT > RT
+ 3 K
Set
AT > RT
+ 2 K
Set
AT > RT
+ 1 K
Set
AT > RT
Set
Coding
Possible change
No frost protection,
adjustment only possible
if code "A3:-9" is
selected.
Note
With settings below 1 °C
there is a risk of pipes
outside the thermal insu-
lation envelope of the
house freezing-up. The
standby mode, in particu-
lar, should be observed,
e.g. during holidays.
Without heating circuit
pump logic function
With heating circuit pump
logic function: Heating
circuit pump OFF, if (see
the following table)
55