7 - 10 MC75 User Guide

Four Slot Ethernet Cradle

Troubleshooting the Four Slot Ethernet Cradle
Table 7-4
Symptom
Attempt by the MC75
to ActiveSync failed.
During
communication, no
data transmits, or
transmitted data was
incomplete.
Cause
MC75 removed
Wait one minute and reinsert the MC75 in the cradle. This allows
from the cradle
the cradle to attempt another synchronization.
while the LED was
blinking green.
Using an outdated
Visit
version of
ActiveSync.
ActiveSync on the
Wait one minute and reinsert the MC75 in the cradle. This allows
host computer has
the cradle to attempt another synchronization.
not yet closed the
previous ActiveSync
session.
Incorrect cable
Ensure the correct cable (Ethernet) is used with the cradle.
configuration.
Communication
Perform setup as described in the MC75 Integrator Guide.
software improperly
configured.
MC75 ActiveSync
On the MC75, tap
disabled or not
button. Then, uncheck the
configured to accept
check box.
network connection.
Host ActiveSync
On the host computer, check
disabled or not
network (Ethernet) Server Connection with this desktop computer.
configured to accept
network connection.
MC75 removed
Replace MC75 in cradle and retransmit.
from cradle during
communications.
MC75 has no active
An icon is visible in the status bar if a connection is currently active.
connection.
Solution
http://www.microsoft.com
for the latest ActiveSync software.
>
Start
ActiveSync
Enable PC sync using this connection:
File
>
>
>
Tools
Options
Options
>
>
Connection Settings
Allow