If Image Quality Declines; Resolving Nozzle Clogging; Stopping The Unit During The Operation - MIMAKI JF-1631 Operation Manual

Uv inkjet printer
Table of Contents

Advertisement

If image quality declines

Corrective measures against troubles in the case where satisfactory image quality is not provided are
described in this station.
Take measures in accordance with actual state of the picture.
If the measures fail restore the device to the normal state, contact your local MIMAKI distributor or MIMAKI
office call for service.
Development
Lines/thin spots are obvious occur
Large ink drop on media
Media is raised during printing and
*1
printing stops.
*1. During printing, media may be raised due to the heat from the UV lamp, causing printing to be stopped.

Resolving nozzle clogging

If nozzle clogging is not resolved even the head cleaning operation of P.2-10 has been executed, check the
following 2 items.
Fill ink with the operation of P.4-20.
Replace ink with the operation of P.4-4.

Stopping the unit during the operation

Press the EMERGENCY SWITCH for stopping the unit urgently
for the safety reason.
One EMERGENCY switch is placed on the front face of the unit
and 2 are placed on each of the back surface and Y-bar
respectively.
Before taking a phenomenon as a trouble
Corrective measure
(1) Execute the head cleaning. (
(2) Clean the wiper and cap. (
(3) If slip of paper is present in the head path, for example,
above the work plate, remove it.
(1) Execute the ink caps cleaning. (
(2) Execute the head cleaning [normal]. (
(3) Dust the media.
(4) Dust the table.
(5) Execute the cleaning for the undersurface of the
carriage.
P.4-8
(6) Set a correct value to the head gap value.
P.3-7
(1) Set new media and start printing.
P.2-10)
P.4-26)
P.4-26)
P.2-10)
5-3
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jf-1610

Table of Contents