High Elevation; Gas Line Installation - Regency Fireplace Products P36-NG4 Natural Gas Owners & Installation Manual

P36 zero clearance direct vent gas fireplace
Table of Contents

Advertisement

P36-NG4 System Data
For 0 to 4500 feet altitude
Burner Inlet Orifi ce Sizes: #37
Max. Input Rating: 3 0 , 0 0 0 B t u / h
Min. Input Rating:
Output Capacity with blower Off:
Output Capacity with blower On:
Minimum Output with blower Off:
Supply Pressure:
Manifold Pressure
(High):
Electrical: 120 V A.C. System.
Circulation Fan: variable speed 130 CFM.
Log Set: Ceramic fi bre, 7 per set.
Vent System: Simpson Dura-Vent Direct
Vent System or FPI Direct Vent System
(Flex)
FPI P36-4 Zero Clearance Direct Vent Gas Fireplace
For 0 to 2000 feet altitude
Burner Inlet Orifi ce Sizes:
Max. Input Rating
15,300 Btu/h
Min. Input Rating
Output Capacity with blower Off
22,600 Btu/h
Output Capacity with blower On
23,000 Btu/h
Minimum Output with blower Off
11,500 Btu/h
For 2000 to 4500 feet altitude
Burner Inlet Orifi ce Sizes:
min.5.0" w.c.
Max. Input Rating
Min. Input Rating
3.8"+/- 0.2"w.c.
Output Capacity with blower Off
Output Capacity with blower On
Minimum Output with blower Off
For 0 to 4500 feet Altitude:
Supply Pressure
Manifold Pressure
Electrical: 120 V A.C. System.
Circulation Fan: variable speed 130 CFM.
Log Set: Ceramic fi bre, 7 per set.
Vent System: Simpson Dura-Vent Direct
Vent System or FPI Direct Vent System
(Flex)
P36-LP4 System Data
#52
30,000 Btu/h
15,000 Btu/h
22,800 Btu/h
23,200 Btu/h
11,700 Btu/h
#53
25,000 Btu/h
12,600 Btu/h
19,000 Btu/h
19,300 Btu/h
11,700 Btu/h
min.12.0" w.c.
(High)
11"+/- 0.2" w.c.
INSTALLATION
Note: Output capacity:
The effi ciency rating of the appliance
is a product thermal efficiency
rating determined under continuous
operating conditions and was
determined independently of any
installed system.
Vent height may or may not change
your effi ciency ratings.

HIGH ELEVATION

This unit is approved in Canada for altitude 0
to 4500 ft. (CAN1 2.17-M91) with the orifi ce
supplied.
GAS LINE
INSTALLATION
The gas line is brought through the right of the
appliance. The gas valve is situated on the right
hand side of the unit and the gas inlet is on the
right hand side of the valve.
The gas line connection may be made of rigid
pipe, copper pipe or an approved fl ex connector.
(If you are using rigid pipe, ensure that the valve
can be removed for servicing.) Since some
municipalities have additional local codes it is
always best to consult with your local authorities
and the CAN/CGA B149 installation code.
For USA installations follow local codes and/
or the current National Fuel Gas Code, ANSI
Z223.1.
When using copper or fl ex connectors use only
approved fi ttings. Always provide a union so
that gas lines can be easily disconnected for
servicing. Flare nuts for copper lines and fl ex
connectors are usually considered to meet this
requirement.
Important: Always check for gas leaks with
a soap and water solution or gas leak detec-
tor. Do not use open fl ame for leak testing.
33