Regency Fireplace Products P121-NG10 Owners & Installation Manual

Panorama p121 / p131 zero clearance direct vent gas fireplace
Table of Contents

Advertisement

Quick Links

Panorama
Zero Clearance Direct Vent Gas Fireplace
STYLE
See Thru
P121-NG10 Natural Gas P121-LP10 Propane
Pier
P131-NG10 Natural Gas P131-LP10 Propane
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach you gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
919-498b
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
P121 / P131
®
MODEL
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Owners &
Installation Manual
www.regency-fire.com
03.01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P121-NG10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Regency Fireplace Products P121-NG10

  • Page 1 Zero Clearance Direct Vent Gas Fireplace Installation Manual www.regency-fire.com STYLE MODEL See Thru P121-NG10 Natural Gas P121-LP10 Propane Pier P131-NG10 Natural Gas P131-LP10 Propane WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The P121 / P131 is a hand crafted appliance and has ® been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The model P121 / P131 has been approved by Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace. ® IMPORTANT: If the unit is to be installed into a bathroom, optional Neo ceramic glass (Part# 360-946 Front or Part# 360- 948 Side) must be purchased and installed in place of the tempered glass supplied with the unit. Regency P121-10/P131-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 3: Manufactured Mobile Home Requirements

    MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Intertek as a Direct Vent Wall Furnace to the following standards: VENTED GAS ® FIREPLACE HEATERS CAN/CGA-2.17-M91, and ANSI Z21.88-2014 • CSA 2.33-2014 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN/CGA 2.17-M91.
  • Page 4: Table Of Contents

    table of contents Installation Log Set Installation ............32 Safety screen Removal ..........34 Important Message ............9 Glass Door Removal............35 Save these instructions ..........9 Finishing Trim...............35 Before You Start .............9 Louvers & Grills ............35 General Safety Information ..........10 Wall Thermostat (Optional) ..........36 Installation Checklist ............10 DC Spark Igniter ............36 Locating Your Gas Fireplace ........10 Battery Installation ............36 Clearances ..............12 Wiring Diagrams ............37 Combustible Mantels ..........12 Operating Instructions Framing And Finishing ..........13 Facing & Finishing Requirements .
  • Page 5 MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE. 4001172 This appliance must be installed in accordance with local codes, if any; if Model/Modèle: P121-NG10/ P131-NG10 APPAREIL FONCTIONNANT AU GAZ NATUREL NATURAL GAS: none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
  • Page 6: For The State Of Massachusetts Only

    requirements MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 7 dimensions P121-10 See Thru Note: These units are non-load bearing. Regency P121-10/P131-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 8 dimensions P131-10 Pier Note: These units are non-load bearing. Regency P121-10/P131-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 9: Installation

    installation IMPORTANT MESSAGE CHILDREN AND ADULTS SHOULD BE SAVE THESE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE- INSTRUCTIONS CIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS The Panorama P121/P131-NG10 or P121/P131- OR CLOTHING IGNITION. LP10 Direct Vent Fireplace must be installed in accordance with these instructions.
  • Page 10: General Safety Information

    installation GENERAL SAFETY INSTALLATION INFORMATION CHECKLIST 1) The appliance installation must conform with Note: These units are local codes or, in the absence of local codes, non-load bearing. with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.
  • Page 11 installation LOCATING YOUR A) P121-10 See Thru GAS FIREPLACE 1) When selecting a location for your fireplace, ensure that the clearances are met as outlined in the "Clearances" section. 2) Provide adequate clearances for servicing. 3) The appliance must be installed on a flat, solid, continuous surface (e.g.
  • Page 12: Clearances

    installation CLEARANCES The clearances listed below are Minimum distances unless otherwise stated (refer to diagrams in the "Locating Your Fireplace" section): Clearance to Combustibles from: Back 0" (0mm) Side 0" (0mm) Floor 0" (0mm) CAUTION REQUIREMENTS: The top, back and sides of the fireplace are defined by standoffs. WARNING: The metal ends of the standoffs may NOT be recessed into combustible construction.
  • Page 13: Framing And Finishing

    installation FRAMING AND FINISHING 1) For ease of installation, frame your fireplace after it is positioned and the vent system is installed. Remember to install the top standoffs. See the "Unit Assembly Prior to Installation" section. Use 2x4's and frame to local building codes. CAUTION: Verify your fireplace dimensions, framing methods and finished wall facing details before framing.
  • Page 14: Facing & Finishing Requirements

    installation FACING & FINISHING REQUIREMENTS This fireplace is supplied with a 3" metal extension trim above the fireplace. The extension trim may be replaced if the framing is faced with a non- combustible material placed flush with the front and side face of the unit and extending from the top of the unit. (ie. tile, slate, etc.) VENTING INTRODUCTION UNIT ASSEMBLY PRIOR TO...
  • Page 15: Exterior Vent Termination Locations

    installation EXTERIOR VENT TERMINATION LOCATIONS Minimum Clearance Requirements Canada Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) Clearance to window or door that may be opened 12"(30cm) 9" (23cm) Clearance to permanently closed window Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm) 18"(46cm) 18"(46cm) from the center line of the terminal (check with the local code) Clearance to unventilated soffit 20"(51cm) 20"(51cm) Clearance to outside corner: with AstroCap Termination Cap. 6"(15cm) 6"(15cm) Clearance to outside corner: with all other approved Termination Caps. 14"(36cm) 14"(36cm) Clearance to inside corner: with AstroCap Termination Cap 6"(15cm) 6"(15cm) Clearance to inside corner: with all other approved Termination Caps. 12"(30cm) 12"(30cm) 13"(33cm) Clearance to each side of center line extended above meter/regulator assembly 36"(90cm) Clearance to service regulator vent outlet 36"(90cm) Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance 12"(30cm) 9" (23cm)
  • Page 16: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    SV4BF TM-4CS Trim Plate-Black 4DT-TP 4DFPB 4DcP SV4LA TM-4TP 16 | Regency P121-10/P131-10 Zero Clearance Direct Vent Gas Fireplace ® Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com...
  • Page 17 Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com...
  • Page 18: Venting Arrangement - Horizontal Terminations

    installation VENTING ARRANGEMENT - HORIZONTAL TERMINATIONS Regency Direct Vent System (Flex) Horizontal Terminations Only ® These venting systems, in combination with the P121-10/P131-10 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the "Exterior Vent Termination Locations"...
  • Page 19: Rigid Pipe Venting Systems

    installation RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations The minimum components required for a basic horizontal termination are: Simpson Duravent Adaptor Horizontal Termination Cap Elbow Rigid Pipe Adaptor Wall Thimble Length of pipe to suit wall thickness (see chart) Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap.
  • Page 20: Rigid Pipe Venting Arrangements

    installation RIGID PIPE VENTING ARRANGEMENTS HORIZONTAL TERMINATIONS REGENCY DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) The diagram below shows examples of horizontal termination arrangements using one, two, or three 90 elbows (two 45 elbows equal one 90 elbow). Note: All Rigid Pipe Systems 1) A maximum of three 90 elbows are permitted.
  • Page 21 installation Horizontal Venting with Three (3) 90 Elbows Horizontal Venting with Two (2) 90 Elbows Option H + H1 + H2 Option H + H1 2' (610mm) Min. 1' (305mm) Max. 3' (914mm) Max. 1' (305mm) Minimum 2' (610mm) Maximum 3' (914mm) Min.
  • Page 22: Rigid Pipe Venting Arrangements - Vertical Terminations

    installation RIGID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS (Propane & Natural Gas) • Vent must be supported at offsets • Maintain clearances to combustibles as listed in the "Clearances" section. • Firestops are required at each floor level and whenever passing through a wall. •...
  • Page 23 installation Vertical Venting with Two (2) 90 Elbows Vertical Venting with Two (2) 90 Elbows Option H + H1 Option V + V1 1' (305mm) Minimum 2' (610mm) Maximum 1' (305mm) Minimum 4' (1.22m) Maximum 2' (610mm) Minimum 6' (1.83m) Maximum 2' (610mm) Minimum 4' (1.22m) Maximum 3' (914mm) Minimum...
  • Page 24: Horizontal Terminations

    installation Vertical Venting with Three (3) 90 Elbows Option V + V1 H + H1 2' (610mm) Minimum 3' (914mm) Maximum 3' (914mm) Minimum 6' (1.86m) Maximum 4' (1.22m) Minimum 9' (2.7m) Maximum 5' (1.5m) Minimum 12' (3.6m) Maximum With the above options, maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal.
  • Page 25: Vertical Terminations

    installation 4) Assemble the desired lengths of pipe and VERTICAL TERMINATIONS elbows. Ensure that all pipes and elbow connections are in the fully twist-locked 1) Maintain the 1-1/4" clearances (air spaces) position and sealed. to combustibles when passing through ceilings, walls, roofs, 5) Cut a hole in the roof centered on the small enclosures, attic rafter, or other drilled hole placed in the roof in Step 2.
  • Page 26: Installation Procedures

    installation 5 or local codes. Note that for steep roof pitches, the vertical height must be Note: To make the 5) Slip the assembled liner and termination increased. A poor draft, or down drafting installation more assembly through the thimble making sure a l l can result from high wind conditions near a e s t h e t i c a l l y...
  • Page 27: Vertical Termination

    installation VERTICAL TERMINATION VERTICAL TERMINATION 4" X 6-7/8" VENTING - VERTICAL FLEX VENT KIT (946-755) 4" X 6-7/8" VENTING 1. Maintain the 1-½” clearance (air space) to combustibles when passing 11. Secure inner fl ex pipe to pipe adaptor by using Mill-Pac over the adaptor. through ceilings, walls, fl oors, enclosures, attic rafters or other nearby Slide the inner pipe over adaptor and secure with 3 screws.
  • Page 28: Flex Vent Components

    installation VERTICAL FLUE EXTENSION KIT (PART #946-756) VERTICAL FLUE EXTENSION KIT (PART # 946-756) 20 foot Flex pipe Extension (Used in conjunction with the 946-755 Vertical Flex kit and 948-367/P flex 4" (100mm) inner pipe to flex adaptor). CEILING FIRESTOP/FIRESTOP SPACER 20ft.
  • Page 29: Conversion From Ng To Lp

    P121 / P131 installation Conversion from NG to LPG CONVERSION FROM NG TO LP for P121-10 / P131-10 using SIT 829 NOVA Gas Valve FOR P121-10/P131-10 USING SIT 829 NOVA GAS VALVE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 8.
  • Page 30: High Elevation

    installation PILOT ADJUSTMENT P121/P131-NG10 System Data 5) The pressure check should be carried out For 0 to 4500 feet altitude with the unit burning and the setting should Periodically check the pilot flames. Correct Burner Inlet Orifice Sizes: be within the limits specified on the safety flame pattern has three strong blue flames: label.
  • Page 31: Wall Mount On / Off Switch And Remote Receiver Installation

    installation WALL MOUNT ON / OFF SWITCH AND REMOTE RECEIVER INSTALLATION REQUIRED FOR ALL INSTALLATIONS - INCLUDING PROFLAME REMOTE CONTROLS IMPORTANT INSTALLATION NOTE: The Receiver must be placed inside the supplied (Low Voltage) junction type wall box and installed into the wall only. DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE.
  • Page 32: Log Set Installation

    LOG SET INSTALLATION installation P121 / P131 LOG SET INSTALLATION Read the instructions below carefully and refer to the 3) Place Log 326 on the front right side of the burner. diagrams. If logs are broken do not use the unit until Ensure that the notches on the far right side of the log they are replaced.
  • Page 33 LOG SET INSTALLATION installation P121 / P131 Repeat step 4 on the opposite side of the burner. 6) Place Log 328 on the middle right side of the burner. Ensure that the log fi ts over the 2nd grate post from the right.
  • Page 34: Safety Screen Removal

    installation SAFETY SCREEN REMOVAL 1. Remove upper and lower louvers if installed. 5. Loosen the 2 screws as shown in locations shown in Diagram 4. 2. Loosen 2 screws in locations shown in Diagram 1. Diagram 4 Diagram 1 6. Pull the bottom bracket down and outward to remove. 3.
  • Page 35: Glass Door Removal

    installation LOUVERS & GRILLS FINISHING TRIM GLASS DOOR REMOVAL 1) Attach the screws provided to the top left 1) Slide the Side Finishing Trim up into the slot 1) Remove the 8 screws that secure the glass and right corners. in the top flange of the fireplace.
  • Page 36: Wall Thermostat (Optional)

    installation WALL THERMOSTAT DC SPARK IGNITER (OPTIONAL) BATTERY INSTALLATION A wall thermostat may be installed if desired, Install the supplied battery into the DC Sparker Box connect the wires as per the wiring diagram. by opening the battery compartment. Use the table below to determine the maximum wire length.
  • Page 37: Wiring Diagrams

    installation WIRING DIAGRAMS No electrical power supply is required for the Caution: Ensure that the wires do A three wire power cord can also be used and gas control to operate. 120 Volt AC power is plugged into a suitable receptacle. not touch any hot surfaces and are needed for the fan switch and blower.
  • Page 38: Operating Instructions

    operating instructions OPERATING LIGHTING SHUTDOWN INSTRUCTIONS PROCEDURE PROCEDURE 1) Read and understand these instructions 1. Press "OFF" on the remote or slide receiver IMPORTANT before operating this appliance. switch from remote to "OFF". Prior to igniting or re igniting the pilot, remove the glass 2) Check to see that all wiring is correct and 2.
  • Page 39: Copy Of The Lighting Plate Instructions

    operating instructions COPY OF THE LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 40: First Fire

    operating instructions FIRST FIRE NORMAL OPERATING SOUNDS OF GAS The FIRST FIRE in your heater is part of the APPLIANCES paint curing process. To ensure the paint is prop- erly cured, it is recommended you burn your fireplace for at least four (4) hours the first time. It is possible that you will hear some sounds from your gas appliance.
  • Page 41: Maintenance

    maintenance liner, and subsequently dripping out the joints, MAINTENANCE Continuous condensation can cause corrosion INSTRUCTIONS DOOR GLASS of caps, pipe, and fittings. It may be caused by having excessive lateral runs, too many Your Regency fireplace is supplied with high ®...
  • Page 42: Removing Valve

    maintenance 13) Undo the pilot tube from the valve with a 8) Remove the Side Base Brick Panels and REMOVING VALVE 7/16" wrench. finally the Long Base Brick Panels. 1) Shut off the gas and electrical supply. 14) Undo the quick drop out thermocouple nut on the valve with a 9mm (metric) wrench.
  • Page 43: Installing Valve

    maintenance FAN REPLACEMENT 6) Replace fan. INSTALLING VALVE 7) Repeat for opposite side/corner. 1) Shut off power. 1) Attach the valve to the valve bracket with the 6 (m5x8 metric) screws provided. 8) Reverse steps 1 - 5 for installation. 2) Remove top louvers.
  • Page 44: P121-10 (See Thru) Main Assembly

    parts list P121-10 (SEE THRU) MAIN ASSEMBLY Part # Description Part # Description Part # Description 360-528 Door Assy Front - Tempered 135. 360-069 Heat Shield - Side 181. Extension Trim - See Thru 360-946 Door Assy Front - Ceramic 146.
  • Page 45: P131-10 (Pier) Main Assembly

    parts list P131-10 (PIER) MAIN ASSEMBLY Part # Description Part # Description Part # Description 360-528 Door Assy Front - Tempered 360-086 Gasket - Relief Door 171. 360-920 Louver Front - Black (set) 360-946 Door Assy Front - Ceramic Relief Door Assembly 360-924 Louver Front - Black/Steel (Optional)
  • Page 46: P121-10/P131-10 Burner Assembly & Log Set

    parts list P121-10/P131-10 BURNER ASSEMBLY & LOG SET Part # Description 360-930 Log Set Front Right Log Front Left Log Middle Left Log Middle Right Log 363-574/P Valve Assembly -NG 363-576/P Valve Assembly -LP 910-578 Valve Only -NG 910-580 Valve Only -LP 360-090 Gasket - Valve Tray Valve Tray...
  • Page 47 notes Regency P121-10/P131-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 48: Warranty

    warranty Limited Lifetime Warranty FPI Fireplace Products International Ltd. (for Canadian customers) and Fireplace Products U.S., Inc. (for U.S. customers) (collectively referred to herein as “FPI”) extends this Limited Lifetime Warranty to the original purchaser of this appliance provided the product remains in the original place of installation. The items covered by this limited warranty and the period of such coverage is set forth in the table below.
  • Page 49 warranty At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective prior to processing or authorizing of any claim. Failure to allow this upon request will void the warranty. All warranty claims must be submitted by the dealer servicing the claim, including a copy of the Bill of Sale (proof of purchase by you).
  • Page 50 warranty Limitations of Liability: The original purchaser’s exclusive remedy under this warranty, and FPI’s sole obligation under this warranty, express or implied, in contract or in tort, shall be limited to replacement, repair, or refund, as outlined above. IN NO EVENT WILL FPI BE LIABLE UNDER THIS WARRANTY FOR ANY INCIDENTAL OR CONSEQUENTIAL COMMERCIAL DAMAGES OR DAMAGES TO PROPERTY.
  • Page 51 warranty Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 53 notes Regency P121-10/P131-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 54 notes 54 | Regency P121-10/P131-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 56 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency and Panorama are trademarks of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2017, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

P131-ng10P131-lp10P121-lp10

Table of Contents