Remote Control(Optional); Wall Switch (Optional); Wall Thermostat (Optional) - Regency Fireplace Products P36-NG4 Natural Gas Owners & Installation Manual

P36 zero clearance direct vent gas fireplace
Table of Contents

Advertisement

REMOTE CONTROL
(OPTIONAL)
Use the FPI Remote Control Kit approved for
this unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
1) Choose a convenient location on the wall
to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fi replace
to that location. Use the Thermostat Wire
Table.
2) Connect the two wires to the gas valve. See
diagram below.
CAUTION
Do not connect millivolt
remote control wires
to 120V wire.
3) Install 3 AAA alkaline batteries in transmitter
and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.
FPI P36-4 Zero Clearance Direct Vent Gas Fireplace
WALL SWITCH
(OPTIONAL)
1) Run the wire through the right or left side
inlet opening. Be careful not to damage
wire.
Note: We recommend a maximum of 15'
of wire but if you wish to go with a
longer run, use the Thermostat Wire
Table.
2) Connect the wire to the wall switch and install
into the receptacle box. See the "Alternate
Wiring Diagram for Wall Switch" section for
wiring diagrams.
CAUTION
Do not connect millivolt
wall switch wire
to 120V wire.
INSTALLATION
WALL THERMOSTAT
(OPTIONAL)
A wall thermostat may be installed if desired,
connect the wires as per the wiring diagram.
Use the table below to determine the maximum
wire length.
Note: Preferable if the thermostat is
installed on an interior wall.
FPI offers an optional programmable thermostat
but any 250-750 millivolt rated non-anticipator
type thermostat that is CSA, ULC or UL approved
may be used.
CAUTION
Do not connect millivolt
wall thermostat wires
to 120V wire.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
50 Ft.
16 GA.
32 Ft.
18 GA.
20 Ft.
20 GA.
12 Ft.
22 GA.
9 Ft.
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

P36-lp4 propane

Table of Contents