Pilot Adjustment; High Elevation; Gas Pipe Pressure Testing - Regency Fireplace Products Panorama P33-10 Owners & Installation Manual

Table of Contents

Advertisement

installation
|
42

PILOT ADJUSTMENT

Periodically check the pilot flames. Correct
flame pattern has three strong blue flames:
1 flowing around the thermopile, 1 around
the thermocouple and 1 flowing across the
burner (it does not have to be touching
the burner).
Note: If you have an incorrect flame
pattern, contact your FPI dealer for
further instructions.
Incorrect flame pattern will have small,
probably yellow flames, not coming into
proper contact with the rear burner or
thermopile or thermocouple.
SIT 829 VALVE DESCRIPTION
1) Gas on/off knob
2) Electronically Operated Hi/Lo
3) Pilot Adjustment
4) Thermocouple Connection - option
5) Outlet Pressure Tap
6) Inlet Pressure Tap
7) Pilot Outlet
8) Main Gas Outlet
9) Alternative TC Connection Point
42 |
Regency
P33-10 Zero Clearance Direct Vent Gas Fireplace
®
P33-NG10 System Data
With Flush Glass:
For 0 to 4500 feet altitude
Burner Inlet Orifice Sizes: #44
Max. Input Rating 20,000 Btu/h
Min. Input Rating 14,000 Btu/h
Supply Pressure
min.5.0" w.c.
Manifold Pressure
(High)
3.5"+/- 0.2" w.c.
P33-LP10 System Data
With Flush Glass:
For 0 to 4500 feet altitude
Burner Inlet Orifice Sizes: #55
Max. Input Rating 19,500 Btu/h
Min. Input Rating 15,500 Btu/h
Supply Pressure
min.11.0" w.c.
Manifold Pressure
(High)
10"+/- 0.2"w.c.

HIGH ELEVATION

This unit is approved in Canada for altitude to
4500 ft. (CSA 2.17). For Natural Gas installations
above 4500 ft. follow current CSA B149.1.
GAS PIPE PRESSURE TEST-
ING
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig.
(3.45 kPa). Disconnect piping from valve at
pressures over 1/2 psig.
The manifold pressure is controlled by a
regulator built into the gas control, and should
be checked at the pressure test point.
Note: To properly check gas
pressure, both inlet and
manifold pressures should
be checked using the valve
pressure ports on the valve.
1) Make sure the valve is in the "OFF" position.
2) Loosen the "IN" and/or "OUT" pressure
tap(s), turning counterclockwise with a
1/8" wide flat screwdriver.
3) Attach manometer to "IN" and/or "OUT"
pressure tap(s) using a 5/16" ID hose.
4) Light the pilot and turn the valve to "ON"
position.
5) The pressure check should be carried
out with the unit burning and the setting
should be within the limits specified on
the safety label.
6) When finished reading manometer, turn
off the gas valve, disconnect the hose and
tighten the screw (clockwise) with a 1/8"
flat screwdriver. Note: Screw should
be snug, but do not over tighten.
S.I.T. VALVE DESCRIPTION
1) Gas on/off knob
2) Manual high/low adjustment
3) Pilot Adjustment
4) Thermocouple Connection - option
5) Outlet Pressure Tap
6) Inlet Pressure Tap
7) Pilot Outlet
8) Main Gas Outlet
9) Alternative TC Connection Point

Advertisement

Table of Contents
loading

This manual is also suitable for:

Panorama p33-ng10Panorama p33-lp10