- Installation and service must be performed by a qualified installer, service agency or the gas supplier. Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. REGENCY FIREPLACE PRODUCTS. 6988 Venture St., Delta, BC Canada, V4G 1H4 919-399a 07.21.15...
Page 2
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY FIREPLACE PRODUCTS. The P36 has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch.
Page 3
INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Intertek as a Vented Gas Fireplace Heater to the following standards: CAN/CGA-2.17-M91, and ANSI Z21.88-2014 • CSA 2.33-2014. This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.
table of contents MA Code - CO Detector..........6 Gas Pipe Pressure Testing ..........35 (for the State of Massachusetts only) ......6 SIT 829 Valve Description ...........35 Unit Dimensions with vignette ........7 Conversion from NG to LP ........36 Unit Dimensions with vignette and Optional Brick Panels ..........37 vignette finishing trim .............8 Log Set Installation ............38...
Page 5
safety decal This is a copy of the label that accompanies each P36 Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit.
installation MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
dimensions UNIT DIMENSIONS WITH VIGNETTE 8 " (841mm) 16 " 15" (381mm) (916mm) 34-3/16 16 " 16 " (864mm) (56mm) (325mm) Optional 3 sided finishing trim (not shown) 38" W x 33-3/4" H P36-10 Zero Clearance Direct Vent Gas Fireplace |...
dimensions UNIT DIMENSIONS WITH VIGNETTE AND VIGNETTE FINISHING TRIM 2 " 2" (953mm) 1-1/4” (26mm) 4 " (324mm) 4 " (375mm) UNIT DIMENSIONS WITH SAFETY SCREEN (#515-506) AND OPTIONAL LOUVERS | P36-10 Zero Clearance Direct Vent Gas Fireplace...
Venting instructions. ANCE. TODDLERS, YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE The P36-NG10 or P36-LP10 Direct Vent Fireplace 5) Inspect the venting system annually for blockage must be installed in accordance with these TO ACCIDENTAL CONTACT BURNS. A and any signs of deterioration.
installation INSTALLATION LOCATING YOUR 7) We recommend that you plan your installation on CHECKLIST GAS FIREPLACE paper using exact measurements for clearances and floor protection before actually installing this 1) Locate appliance. Refer to the following 1) When selecting a location for your fireplace, appliance.
installation CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions. Clearance to Combustibles from: Back 0"...
installation CLEARANCES Min. 6" (152mm) MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: Maximum 1-1/2" projection at 2" minimum clearance. 12 | P36-10 Zero Clearance Direct Vent Gas Fireplace...
installation COMBUSTIBLE MANTEL CLEARANCES Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: Mantel starts at *1" deep and ends at *12" deep. **For Vignette with Vignette Finishing Trim flush finish, all materials (framing & finishing) below the mantel and the width of the Vignette finishing trim, (37 1/2") must be non-combustible if a lower mantel is desired.
installation FRAMING 1) Determine the total thickness of facing material (e.g. non combustible plus ceramic tiles) to allow the finished surface to be flush with the front of the unit. Total facing thickness can vary from 1/2" (13mm) to 1-1/4" (32mm) thick with Vignette only, Vignette + Vignette Finishing Trim Stepped Finish and Safety Screen and Louvers.
installation FRAMING WITH FRAMING WITH VIGNETTE FRAMING WITH VIGNETTE FACEPLATE/VIGNETTE FACEPLATE & FINISHING TRIM LOUVERS AND SAFETY SCREEN FINISHING TRIM, STEPPED FINISH FINISHED FLUSH Frame in the enclosure for the unit with framing Frame in the enclosure for the unit with framing material.
installation FINISHING IMPORTANT FINISHING DETAIL NOTE: Before placing unit into final position - it is important to know the total thickness / height of finished hearth (tile, carpet, etc.) The base of the fireplace should be level or higher than the finished hearth height. Diagram 1 Note: All non-combustible and combustible facing material should...
installation WALL MOUNT ON / OFF SWITCH AND REMOTE RECEIVER INSTALLATION REQUIRED FOR ALL INSTALLATIONS - INCLUDING PROFLAME REMOTE CONTROLS IMPORTANT INSTALLATION NOTE: The Receiver must be placed inside the supplied (Low Voltage) junction type wall box and installed into the wall only. DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE.
installation UNIT ASSEMBLY 2) Fold out the two nailing strips on each side. 1) Mount Top Facing Support using the 3 supplied screws into the three pre- PRIOR TO punched screw holes on the top front of INSTALLATION the unit. Use hole positions A, B, or C depending on your facing depth.
installation EXTERIOR VENT TERMINATION LOCATIONS Minimum Clearance Requirements Canada Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) Clearance to window or door that may be opened 12"(30cm) 9" (23cm) Clearance to permanently closed window Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm) 18"(46cm) 18"(46cm) from the center line of the terminal (check with the local code)
installation VENTING DIRECT VENT SYSTEM (FLEX) HORIZONTAL TERMINATIONS ONLY These venting systems, in combination with the P36 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the "Exterior Vent Termination Locations"...
4DT-FS 4DFSP 4DFS SV4BF TM-4CS Trim Plate-Black 4DT-TP 4DFPB 4DcP SV4LA TM-4TP Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com P36-10 Zero Clearance Direct Vent Gas Fireplace |...
Page 22
Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com...
Direct Vent , American Metal Products Ameri Vent Direct Vent, Security Secure Vent , Selkirk Direct-Temp. AstroCap is a proprietary trademark of ® Regency Fireplace Products. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. P36-10 Zero Clearance Direct Vent Gas Fireplace |...
installation RIGID PIPE VENTING ARRANGEMENTS HORIZONTAL TERMINATIONS RegencyDIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 elbow (two 45 elbows equal one 90 elbow). Note: Must use optional rigid pipe adaptor (Part # 510-994) when using Rigid Pipe venting systems. All Rigid Pipe Systems 4"...
Page 25
installation Horizontal Venting with Two (2) 90 Elbows One 90 elbow = Two 45 elbows. Option H + H1 W i t h t h e s e o p t i o n s , 0' Min. 2' Max. maximum total pipe length 1' Min.
installation RIGID PIPE VENTING ARRANGEMENTS VERTICAL TERMINATIONS (Propane & Natural Gas) The shaded area in the diagram shows all allowable combinations of straight vertical and elbow, with Rigid Pipe vent systems for Propane offset to vertical terminations, using two 90 and Natural Gas.
Page 27
installation • Vent must be supported at offsets. • Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles. Note: Must use optional rigid pipe adaptor when using rigid vent systems (Part # 510-994). P36-10 Zero Clearance Direct Vent Gas Fireplace |...
Page 28
installation Vertical Venting with Two (2) 90 Elbows One 90 elbow = Two 45 elbows. Option V + V1 With these options, 0' Min. 2' Max. 1' Min. max. total pipe length 1' Min. 4' Max. 2' Min. is 30 feet with min. of 6 feet total vertical 2' Min.
installation VERTICAL TERMINATION - CO-LINEAR FLEX SYSTEM INTO A MASONRY CHIMNEY THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. as possible, avoid unnecessary bending. This appliance is designed to be attached to The Air Intake pipe must be attached to the inlet air collar of the termination cap.
installation VENTING ARRANGEMENTS - VERTICAL TERMINATION with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations. 30 | P36-10 Zero Clearance Direct Vent Gas Fireplace...
installation DURA-VENT HORIZONTAL b) Horizontal runs of vent must be supported every three feet. Wall straps TERMINATIONS are available for this purpose. Install the vent system according to the 5) Mark the wall for a 10" x 10" square hole. The manufacturer's instructions included with center of the square hole should line up with the components.
installation DURA-VENT VERTICAL 4) Assemble the desired lengths of pipe and TERMINATIONS elbows. Ensure that all pipes and elbow connections are in the fully twist-locked position and sealed. 1) Maintain the 1-1/4" clearances (air spaces) to combustibles 5) Cut a hole in the roof centered on the small when passing through ceilings, drilled hole placed in the roof in Step 2.
installation 4) Separate the 2 halves of the wall thimble and be increased. A poor draft, or down drafting N o t e : To m a k e securely fasten the one with the tabs to the can result from high wind conditions near big t h e i n s t a l l a t i o n outside wall making sure that the tabs are...
HIGH ELEVATION P36-NG10 System Data P36-LP10 System Data This unit is approved in Canada for altitude 0 For 0 to 4500 feet altitude For 0 to 2000 feet altitude to 4500 ft. (CAN1 2.17-M91) with the orifice Burner Inlet Orifice Sizes: #37 Burner Inlet Orifice Sizes: supplied.
installation PILOT ADJUSTMENT GAS PIPE PRESSURE SIT 829 VALVE DESCRIPTION TESTING 1) Gas on/off knob Periodically check the pilot flames. Correct 2) Electronically Operated Hi/Lo flame pattern has three strong blue flames: The appliance must be isolated from the gas 3) Pilot Adjustment 1 flowing around the thermopile, 1 around supply piping system by closing its individual...
installation CONVERSION FROM NG TO LP Conversion from NG to LPG for FOR P36-10 USING SIT 829 NOVA GAS VALVE P36D-10 / P36-10 THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Remove burner orifice with a 1/2"...
installation OPTIONAL BRICK PANELS 5. Install the 2 brick retaining clips, one on each side. 1. Remove Faceplate, Safety Screen if already installed. 2. Undo the bottom 2 door latches and open and remove glass door. Remove logs. Note: The logs must not be in the unit. 3.
GAS FIREPLACE installation LOG SET INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. The gas log kit (Part # 512-930) contains the following: Place Log 02-49 on the rear log support pins with the fl...
Page 39
GAS FIREPLACE installation Position Log 02-53 across the cutouts in Logs 02-49 and Sit Log 02-50 on the front left side of the burner. Push the 02-51 with the notch on the left side of the log fi tting into back of the log against the 2 front brackets with the notch the 2nd grate tab.
Page 40
GAS FIREPLACE installation 10) Place the embers on the front of the burner tray in the Place Log 02-52 between Logs 02-51 and 02-49 and on places shown on the photo. the indentation on Log 02-54. The bottom right end sits behind the rear grate tab.
installation STANDARD FLUSH DOOR The standard flush door comes with a black frame. To install the frame, Be careful that the glass gasket does not roll up; there must be a gap simply hook the top door flange onto the top of the unit and swing the between the gasket and the door lip to ensure that the door sits securely door towards the unit, see Diagram 1.
installation VIGNETTE FACEPLATE AND SAFETY SCREEN INSTALLATION Vignette faceplate and safety screen installation 1. Hook the outer Vignette frame onto the unit. Brackets on the frame hook on to tabs in the unit. Note: Use the inner slots for the P36/P36E units and the outer slots for the P36D. P36D P36/P36E Adjustable Mounting Brackets are in increments...
installation OPTIONAL VIGNETTE INLAY OPTIONAL VIGNETTE INLAY INSTALLATION NOTE: Inlay not exactly as shown below. 1. Remove Inner Vignette Frame from unit if already installed. 5. Secure the Inlay in position with supplied brackets, washers, and nuts as shown. 2. Line up the inlay top bracket in the space between the safety screen frame and Vignette Frame.
installation VIGNETTE FINISHING TRIM VIGNETTE FINISHING TRIM INSTALLATION *If finishing the unit Flush with Vignette Finishing Trim - remove top nailing strip from unit if installed–use nailing *If finishing the unit Flush with Vignette Finishing Trim - remove top nailing strip from unit if installed–use nailing strip supplied with top trim piece. Side strip supplied with top trim piece.
installation OPTIONAL FINISHING TRIM OPTIONAL FINISHING TRIM NOTE: Remove the safety screen, Vignette Faceplate (P33 units only: remove 2 screws securing lower legs of Faceplate) and glass door prior to installing the Finishing Trim. Install the Finishing Trim sides as shown in the diagram, line up the holes in the side trim with the holes in the firebox side.
installation SAFETY SCREEN INSTALLATION - SAFETY SCREEN INSTALLATION - MUST BE USED WITH OPTIONAL LOUVERS MUST BE USED WITH OPTIONAL LOUVERS 1. Hook the safety screen frame over the glass door frame. 2. Gently lower screen on to glass door frame–two (2) magnets located on inside lower part of the screen frame will secure the screen to the glass door frame. 3. To remove–reverse steps. Magnet locations OPTIONAL FLUSH LOUVERS INSTALLATION - USED WITH SAFETY SCREEN # 515-506 07.21.15 919-558a 1.
installation WALL THERMOSTAT DC SPARK IGNITER (OPTIONAL) BATTERY INSTALLATION A wall thermostat may be installed if desired, Install the supplied battery into the DC Sparker Box connect the wires as per the wiring diagram. by opening the battery compartment. Use the table below to determine the maximum wire length.
installation WIRING DIAGRAMS NOTE: Even if the fan is not purchased This heater does not require a 120V A.C. sup- (Do not cut the ground terminal off under with the unit, it is still a good idea to ply for operation. In case of a power failure, the any circumstances.) bring power to the receptacle box burner switch and the optional remote control/...
installation OPTIONAL WALL THERMOSTAT INSTALLATION A wall thermostat may be installed if desired. Recommended: The wall thermostat should be mounted beside the Remote/Unit Receiver which comes standard with the appliance. 1) Run wires from thermostat into the unit using the appropriate wire gauge-see chart below. Thermostat Wire Table CAUTION Recommended Maximum Lead Length...
installation OPTIONAL FAN INSTALLATION OPTIONAL FAN INSTALLATION 120 Volt AC power is needed for the fan. The fan can be hard wired if desired. The outlet should be installed in the recep- tacle box on the left hand side by a qualified electrician. The neutral (wider) slot of the polarized outlet should be at the top.
operating instructions OPERATING LIGHTING SHUTDOWN INSTRUCTIONS PROCEDURE PROCEDURE IMPORTANT 1) Read and understand these instructions 1. Press "OFF" on the remote or slide receiver switch before operating this appliance. from remote to "OFF". Prior to igniting or re igniting the pilot, remove the glass 2) Check to see that all wiring is correct and 2.
operating instructions COPY OF THE LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
operating instructions AERATION NORMAL OPERATING FIRST FIRE ADJUSTMENT SOUNDS OF GAS The first fire in your fireplace is part of the paint APPLIANCES curing process. To ensure that the paint is properly The air shutter can be adjusted by moving the cured, it is recommended that you burn your adjusting wire up or down.
maintenance MAINTENANCE GLASS GASKET 3. Check for evidences of excessive condensation, such as water droplets forming in the inner INSTRUCTIONS liner, and subsequently dripping out the joints, If the glass gasket requires replacement use a Continuous condensation can cause corrosion tadpole glass gasket for the Flush Front (Part # 1.
maintenance REMOVING VALVE INSTALLING VALVE 10. Remove 10 screws securing the valve tray as- sembly in place (Diagram 3) and then lift the entire assembly out (Diagram 4). 1. Shut off the gas and electrical supply. 1. Attach the valve to the valve bracket with the 4 (m5x8 metric) screws provided.
parts list BURNER ASSEMBLY & LOG SET Part # Description 515-474/P Valve Assy - Natural Gas 515-476/P Valve Assy - Propane Valve Tray - NG/LP 430-055 Gasket - Valve Access Plate 911-084 SIT Valve 829 - NG 911-085 SIT Valve 829 - NG Valve Bracket Firebox Base 910-038...
parts list VIGNETTE FACEPLATE AND FINISHING TRIM Part # Description 515-922 Vignette Platinum 515-923 Vignette Black Chrome 515-924 Vignette Black 515-926 Vignette Tuscan Sunset 515-918 Vignette Door Inlay Black Chrome 515-919 Vignette Door Inlay Metallic Black 515-920 Vignette Door Inlay Tuscan Sunset 515-922 Vignette Front Platinum 515-928...
parts list SAFETY SCREEN AND LOUVERS Part # Description 515-922 Flush louvers black 515-506 Safety Screen 948-216 Regency Logo Plate ® 60 | P36-10 Zero Clearance Direct Vent Gas Fireplace...
Page 61
notes P36-10 Zero Clearance Direct Vent Gas Fireplace |...
Page 62
notes 62 | P36-10 Zero Clearance Direct Vent Gas Fireplace...
Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Excalibur Product. This warranty is not transferable.