Mounting Accessory Kit - H3C S5500-HI Switch Series Installation Manual

S5500-hi switch series
Hide thumbs Also See for S5500-HI Switch Series:
Table of Contents

Advertisement

Table 3 Rack-mounting restrictions and guidelines
Switch model
S5500-34C-HI
S5500-58C-HI
S5500-34F-HI
S5500-34C-PWR-HI
S5500-58C-PWR-HI
S5500-28SC-HI
S5500-52SC-HI

Mounting accessory kit

Accessories
One pair of 1U front mounting
brackets (See
One pair of 1U rear mounting
brackets, two load-bearing screws
(See
Figure
One pair of chassis rails and one pair
of slide rails (See
Grounding cable with a one-hole lug
(for connecting to the rear grounding
point)
Mounting method
Rack-mounting by using front
mounting brackets
(S5500-34C-HI,
S5500-58C-HI, and
S5500-34F-HI)
Rack-mounting by using front
and rear mounting brackets
(S5500-34C-PWR-HI and
S5500-58C-PWR-HI)
Rack-mounting by using front
and rear mounting brackets
(S5500-28SC-HI and
S5500-52SC-HI)
Rack-mounting by using front
mounting brackets and
mounting rail assemblies
(S5500-28SC-HI and
S5500-52SC-HI)
Figure
5)
6.)
Figure
7)
Restrictions and guidelines
Install the front mounting brackets at the port-side or
power-side mounting position as needed.
For the S5500-58C-HI, if you are installing an
LSP5GP8P0 interface card, make sure the rack
depth is 800 mm (31.50 in) or 1000 mm (39.37 in).
Install the front mounting brackets at the port-side or
power-side mounting position as needed.
Make sure the rack depth is 800 mm (31.50 in) or
1000 mm (39.37 in).
Install the front mounting brackets at the port-side
and the load-bearing screw at the power-side.
Make sure the rack depth is between 389 mm
(15.32 in) and 555 mm (21.85 in).
Use the grounding port at the rear panel for
grounding.
H3C recommends that you use this installation
method for enterprise networking.
Install the front mounting brackets at the power-side
and the rack mounting rail kit at the port-side.
Make sure the rack depth is between 612 mm
(24.09 in) and 832 mm (32.76 in).
Choose side grounding point or rear grounding
point as needed. If you use side grounding point,
connect the two-hole lug grounding cable to the side
grounding point on the chassis.
H3C recommends that you use this installation
method for data center networking.
S5500-34C-HI
S5500-34C-PWR-HI
S5500-58C-HI
S5500-58C-PWR-HI
S5500-34F-HI
Supplied with the
Supplied with the
switch
switch
Supplied with the
N/A
switch
N/A
N/A
Supplied with the
Supplied with the
switch
switch
6
S5500-28SC-HI
S5500-52SC-HI
Supplied with the
switch
Supplied with the
switch
Optional
Supplied with the
switch