VISTA-10SE Installation and Setup Guide
3. To meet NFPA 72 requirements, you must use a supervisory module to supervise power
(e.g., System Sensor No. A77-716B Relay module).
+
AUX PWR
OUTPUT
_
TERMINALS
TO HI SIDE OF
ZONE 5
TO LO SIDE
Compatible System Sensor 4-Wire Smoke/Combustion Detectors
1412
2412
2412TH
A77–716B
2112/24T

Programming Hardwired Zones

Each zone must be programmed into the system using the 56 Zone Programming Mode or
58 Expert Programming Mode, which assigns characteristics that define the way the system
responds to faults on that zone. Refer to the ZONE RESPONSE TYPE DEFINITIONS and
ZONE PROGRAMMING sections for specific instructions on programming hardwired zones.
4-2
5
4
+
+
HEAT
DETECTOR
_
Figure 7. 4-wire Smoke Detector Connections (Zone 5)
4-wire ionization products of combustion detector
4-wire photoelectric smoke detector
4-wire photoelectric smoke detector w/135°F (57°C) heat detector
EOL relay module (supervisory module for wired 4-wire fire zone)
Low-profile 4-wire photoelectric smoke detector w/135°F (57°C) heat
detector
WWW.DIYALARMFORUM.COM
4-WIRE SMOKE
OR COMBUSTION
DETECTORS
+
_
HEAT
DETECTOR
_
+
BLK
_
VIOLET
1000
OHMS
EOLR
RED
EOL
POWER
SUPERVISION
RELAY MODULE
A77-716B