VISTA-10SE Installation and Setup Guide
Type 05
Trouble by Day/
Alarm by Night
Type 06
24-hour Silent Alarm
Type 07
24-hour Audible Alarm
Type 08
24-hour
Auxiliary Alarm
Type 09
Supervised Fire
5806/5807/5808
Type 10
Interior w/Delay
13-2
Zone type 05 is usually assigned to a zone that contains foil-protected doors
or windows; or covers a sensitive area (e.g., stock room, drug supply room,
etc.) It can also be used on a sensor or contact in an area where immediate
notification of an entry is desired.
Zone Characteristics
Provides an instant alarm when armed in AWAY, STAY, INSTANT, or
MAXIMUM (night) mode.
Provides a latched trouble sounding from the keypad and, if desired, a
central station report during the disarmed state (day).
Zone type 06 is usually assigned to a zone containing an Emergency button.
Zone Characteristics:
Sends a report to the central station but provides no keypad display or
sounding.
Zone type 07 is usually assigned to a zone containing an Emergency button.
Zone Characteristics:
Sends a report to the central station, and provides alarm sounds
externally and at the keypad.
Zone type 08 is usually assigned to a zone containing a button for use in
personal emergencies or to a zone containing monitoring devices (e.g., water
or temperature sensors, etc.).
Zone Characteristics:
Sends a report to the central station and provides an alarm sound at the
keypad. (No bell output is provided and there is no keypad timeout.)
Zone type 09 can be assigned to any wireless zone used as a fire zone. This
zone type is always active and cannot be bypassed.
Zone Characteristics:
Bell output will pulse when this zone type is alarmed.
01000-020-V0
Zone type 10 is bypassed when the panel is armed in the STAY or INSTANT
mode.
Zone Characteristics:
Entry delay #1 (with programmed entry time) when armed in the AWAY
mode.
Entry delay begins whenever sensors in this zone are violated,
regardless of whether an entry/exit delay zone was tripped first.
No entry delay when armed in the MAXIMUM mode.
Exit delay regardless of the arming mode selected.