ADEMCO Vista-10SE Installation And Setup Manual page 42

Hide thumbs Also See for Vista-10SE:
Table of Contents

Advertisement

VISTA-10SE Installation and Setup Guide
If a different Installer code is subsequently programmed, use it instead of 4111 to gain
access to the Programming mode.
When you enter the Program mode, data field 20 is displayed (this is the first data field in
the system). The system now accepts entries for field 20.
Programming a Data Field
1. Press [ ]+ Field No. (for example, 21), then make the desired entry.
2. When you have completely programmed a data field, the keypad beeps three times and
then automatically displays the next data field in sequence. To go to a different field,
press [ ] plus the desired field number.
3. If the number of digits that you need to enter in a data field is less than the maximum
digits available (for example, the phone number field), enter the desired data, then press
[ ] and the next data field number to be programmed.
4. If you try to enter a nonexistent field, the keypad will display NOT USED
Error). Simply re-enter [ ] plus a valid field number.
Reviewing a Data Field/Erasing an Entry
Press [#] + Field No. Data is displayed for that field number. No changes are accepted in
this mode.
To delete an entry in a field, press [ ] + Field No. + [ ] (applies only to fields 40- 43, and
94).
Interactive Mode Programming ( 56, 58, 80, 81, and 82)
Typical prompt displayed
during Interactive mode
programming:
Enter Zn Num.
(00 = Quit)
Loading Factory Defaults
To load the factory defaults, enter the Programming mode, press 97, then exit the
Programming mode.
Do not press 97 to load defaults if any programming has been done previously. If you do, data
already programmed into the system will be changed!
96 resets all the subscriber account numbers and CSID in preparation for an initial
download.
Exiting the Programming Mode
99 allows re-entry into the Program mode using Installer Code + 8 0 .
98 prevents re-entry into the Programming mode using the Installer code.
12-2
Press [ ] + Interactive Mode No. (for example, 56). The
alpha keypad displays the first of a series of prompts requesting
entries.
A detailed procedure (with displays of prompts) is provided in
01
later sections of this manual.
Ç
Zone Number
Interactive Mode
56 Zone Programming
58 Expert Mode
80 Output Relay
81 Zone List
82 Alpha Programming
WWW.DIYALARMFORUM.COM
Used to Program
Zone characteristics, report codes, alpha
descriptors, and serial numbers
Zone characteristics, report codes, and
Programming
serial numbers.
4204 Relay module
Programming
Zone lists for relay control
Programming
Zone alpha descriptors