ECOR HD 16X1 DVR
6.9.5

I/O Control

The I/O Control setup menu is used to define the settings for controlling the DVR through RS-485 communication
protocol and for DVR to control the connected PTZ cameras.
PTZ Protocol: Select PTZ protocol, choose from the following protocols: Transparent, Pelco_D, Pelco_P,
Everfocus or Samsung. (Note: All cameras on the RS-485 bus must use the same protocol)
485 ID: This is the ID used by the EKB500 to send commands to the DVR. On an RS-485 connection, every device
(PTZ, DVR and controller) must be assigned an unique ID number between 0 and 127.
Baud Rate: This field is to set the speed at which is used to transmit instruction or information through the
RS-485 port on the DVR. There are eight different speeds: 1200 BPS, 2400 BPS, 4800 BPS, 9600 BPS, 19200 BPS,
38400 BPS, 57600 BPS and 115200 BPS.
Data Bit: This field is the data bit at which you will be transferring. There are two settings for this option: 8 or 7.
Stop Bit: This field is to set the stop bit for the RS232 connection. There are two different stop bits, 1 or 2.
Parity: This field is to select the parity level at which you will be connected. You can choose between None, Odd,
or Even parity levels.
Control: One remote control can be used to operate four DVRs. The DVR to be addressed is selected by pressing
the key corresponding to its ID number on the IR Remote control. Please refer to Appendix E: IR Remote Control.
Type: Select Text Insert for using POS system; select Control for using EKB500 keyboard and PTZ camera.
IR Controller ID: Set up an ID for the DVR and allow the IR remote control to control this DVR.
116