When twin cycle is active the automatic deflector inside fold
unit option is not available (See TR-7A operator manual
chapter 8). In that case the equal number of folds rule
applies to all TR-7A stations that process documents that
must be folded.
Twin cycle option is required for Automix
Feed unit FE-7, FE-9, ST-1
Feed unit FE-7, FE-9, ST-1
Feed unit FE-7, FE-9, ST-1
Feed unit FE-7, FE-9, ST-1
Refer to FE-7/FE-9 (see Fig. 40) and operator manual
section 5.3. The display A can be set to P. Service personnel
can program P for any figure between 10 and 25.
TM
.
Fig. 40
Feed unit FE-8
Feed unit FE-8
Feed unit FE-8
Feed unit FE-8
OMR reading code
The OMR reading code of the FE-8 can contain additional
marks to:
• select other feed units on the transport unit to feed.
• control the moistening system of the inserter.
• select the exit of the sorter.
• select the hopper of the inserter (Automix
35.
• check the sequence of the pages fed (additional security).
• check the OMR reading code (additional security).
1-800-543-5454
www.officezone.com
TM
) see page