Installer Section; Appliance Data; General Installation Requirements - Valor regency 328 Installation & Servicing Instructions Manual

Radiant / convector
Table of Contents

Advertisement

Valor Folium Format U/down 12/4
INSTALLATION & SERVICING INSTRUCTIONS

1.APPLIANCE DATA

This appliance does not contain any component
manufactured from asbestos or asbestos related
products.
The appliance data label is on the inner face of the
back panel at the lower left hand side. It is visible
when the outer case is removed.
Gas:
Natural (G20)
Inlet pressure:
20mbar (8in. w.g.)
Input - Max:
5.28kW (18,000Btu/h)
(Gross) Min:
1.25kW (4,300Btu/h)
Output - Max:
3.2kW (10,900Btu/h)
Min:
0.56kW (1,900Btu/h)
Burner injectors:
Upper (Centre radiant)
Bray cat 28 size 120
Lower (Outer radiants)
Bray cat 28 size 250B
Burner test pressure
(cold):
18.3mbar (7.2in w.g.)
Inlet pipe connection:
Rp1/4 (1/4" BSP)
Pilot & Atmosphere
sensing device
SIT ref. OP9044
Ignition:
Piezo electric
Integral with gas tap
Aeration:
Non-adjustable.
5/22/00
9:33 AM
Page 4
2. GENERAL INSTALLATION
REQUIREMENTS
For the user's protection, in the United
2.1
Kingdom it is the law that all gas appliances
are installed by competent persons in
accordance with the current edition of the Gas
Safety (Installation and Use) Regulations.
Failure to install the appliance correctly could
lead to prosecution. The Council for the
Registration of
requires its members to work to recognised
standards.
In the United Kingdom the installation must
also be in accordance with:
A. These instructions.
B. All the relevant parts of local regulations.
C. The current edition of the Building Regulations
issued by the Department of the Environment
and the Welsh Office or the Building
Standards (Scotland) Regulations issued by
the Scottish Development Department.
D. All relevant codes of practice.
E. The relevant parts of the current editions of the
following British Standards:-
BS 715
BS 1289 Part 1
BS 4543 Part 2
BS 5440 Part 2
BS 6461 Part 1
In the Republic of Ireland the installation must also conform with
the relevant parts of:
a) The current editions of:-
b)
All relevant national and local rules in force.
The appliance must not stand on a carpet or
2.2
any other combustible material.
If a panel has to be fitted to the fireplace opening to meet the
required opening sizes shown in these instructions it must be
made of non-combustible material.
The appliance can be installed in the
2.3
following situations.
Page 4
Gas Installers (CORGI)
BS 1251
BS 1289 Part 2
BS 5440 Part 1
BS 5871 Part 1
BS 6891
IS 813
ICP3

Hide quick links: