Standby Mode
Standby Screen
setup adjustments can be made without interfering
with other systems operating in the same location.
The screen displays rf OFF to remind the user that
the unit is not transmitting.
While the unit is in the standby mode, access the set-
up screens using the AUDIO and FREQ buttons and
make adjustments using the Up and Down arrows.
Selecting the Compatibility Mode
Digital Hybrid Wireless
compatibility mode
IFB compatibility mode
press the AUDIO and FREQ buttons.
3) Press either AUDIO or FREQ button to select the
compatibility screen and use the Up and Down ar-
rows to select the desired mode.
The following Compatibility Modes are available:
• Digital Hybrid mode:
• IFB Series mode:
4) Simultaneously press the AUDIO and FREQ but-
tons to exit this mode and turn off the power.`
Rio Rancho, NM
Press the AUDIO and
FREQ buttons briefly to
place the unit in Standby
Mode. In this mode the RF
output is turned off so all
The transmitters will work
with Digital Hybrid and IFB
analog receivers. The unit
automatically enters the
®
Standby Mode when
selecting compatibility.
1) Set the receiver's audio
controls to minimum.
2) From a power off con-
dition, hold down the Up
arrow, then simultaneously
CP Hbr
CP IFb
Super-Minature Belt Pack Transmitters
Setting Transmitter Operating Frequency
Frequency displayed
in MHz
Frequency displayed as
two-digit hexadecimal
number
right switch settings on earlier analog transmitters that
used mechanical rotary switches to adjust frequency.
The hexadecimal notation is also easier to remember
than a six character frequency and is supported on
the receiver LCD.
1) Press the FREQ button to select either the MHz
screen or the hexadecimal screen.
2) While holding the FREQ button, use the Up or
Down arrow buttons to move the operating fre-
quency up or down from the current setting.
Note: The operating frequency displayed on the
LCD wraps as it reaches the upper or lower end
of its range.
Adjusting the Low Frequency Roll-off
Repeatedly press the AUDIO button until the LF roll-
off adjustment screen appears. Then press and hold
the AUDIO button while selecting the desired roll-off
frequency with the UP and DOWN arrows.
The roll-off frequency can be set to 35, 50, 70, 100,
120 and 150 Hz.
The frequency can be
displayed either in MHz or
as a two-digit hexadecimal
number and can be set in
the Standby Mode or
when the transmitter is
powered up. The hexa-
decimal numbering
system is unique to
Lectrosonics where two
alphanumeric characters
correspond to the left and
9
Need help?
Do you have a question about the SMDB/E01 Series and is the answer not in the manual?