Technical Data; Electrical Data - Kaco Powador 2002 Operating Manual

Hide thumbs Also See for Powador 2002:
Table of Contents

Advertisement

Technical Data

4
Technical Data
4.1

Electrical Data

Input levels
Max. recommended PV generator power [W]
DC MPP range from [V] to [V]
Operating range from [V] to [V]
Starting voltage [V]
Open circuit voltage [V]*
Max. rated current [A]
Number of strings
Number of MPP controls
Polarity safeguard
* To protect the electronic system, the grid-feed is made at < 550 V.
Output levels
Rated power [VA]
Grid voltage [V]
Rated current [A]
Rated frequency [Hz]
cos phi
Number of feed-in phases
Distortion factor [%]
General electrical data
Maximum effi ciency
European effi ciency
Internal consumption: Standby [W] /
operation [W]
Feed-in starts at [W]
Circuit design
Clock frequency
Grid monitoring
CE conformity
Table 2:
Electrical data
Operating Instructions for Powador 2002-6002_EN
2002
3002
2 000
3 000
125 to 510
125 to 295
125
14.3
13.5
Short-circuit diode
1 650
2 500
7.2
10.9
0.80 over-excited ... 0.80 under-excited
95.9 %
96.0 %
95.3 %
95.4 %
10
15
Galvanically isolating high-frequency DC/DC converter with down-
stream self-commutated inverter
Automatic disconnection device in accordance with
DIN VDE 0126-1-1:2006-02
4202
5002
4 200
5 000
200 to 510
200 to 300
200
600
18.5
22.4
3
1
3 500
4 200
184 to 264 V
15.2
18.3
50
1
<3
95.9 %
95.9 %
95.1 %
95.3 %
0.4 / < 5
25
25
17 kHz
yes
6002
6 000
26.5
4 600
20.0
95.9 %
95.3 %
25
Page 15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powador 5002Powador 6002Powador 3002Powador 4202

Table of Contents