Technical Data; Electrical Data - Kaco Powador 12.0 TL3 - INT Operating Manual

Table of Contents

Advertisement

Technical Data

4
Technical Data
EN
EN
4.1

Electrical data

Input levels
Recommended power range of the generator [kW]
DC MPP range from [V] to [V]
Operating range from [V] to [V]
Starting voltage [V]*
No-load voltage (U
Max. input current [A]
Max. power per MPP tracker [W]
Number of strings
Number of MPP trackers
max. short-circuit current (I
max. input source feedback current [A]
Polarity safeguard
Output levels
Rated power [VA]
Grid voltage [V]
Rated current [A]
Contribution to maximum peak current Ip (îp)
Short circuit current
(Ik'' First cycle RMS value) [A]
Inrush current [A]
Rated frequency [Hz]
cos phi
Number of feed-in phases
Distortion factor (THD) [%]
General electrical data
Max. efficiency [%]
European efficiency [%]
Self consumption: night [W]
Feed-in starts at [W]
Circuit design
Protection class / over voltage category
Grid monitoring
Table 1:
Electrical data
Page 10
) [V]
OC max
) [A]
SC max
12.0 TL3
14.0 TL3
12
14
280 ... 800
350 ... 800
200 ... 950
1,000 (start up to 1,000)
2 x 18.6
10,200
12,800
2 x 2
2 x 22.4
Short-circuit diode
10,000
12,500
400/230 (3/N/PE)
3 x 14.5
3 x 18.1
62,4
18,6
4,52
50 / 60
0.30 inductive ... 0.30 capacitive
2.22
98.0
98.0
97.5
97.6
Transformerless
3 / III
Country-specific
Operating Instructions Powador 12.0 TL3-20.0 TL3
18.0 TL3
20.0 TL3
18
20
420 ... 800
470 ... 800
250
14,900
14,900
2
0
15,000
17,000
3 x 21.8
3 x 24.6
3
98.0
97.9
97.7
97.6
1.5
20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents