Maintenance/Troubleshooting
Authorised electrician
Status
Display
FS
66
Instrument trans-
former fault
FS
70
Fan error
FS
77
DC disconnect
disconnect
FS
Confi g. error
Invalid CRC
Table 7:
Operating statuses and fault messages on the display
Operating Instructions for Powador 2002-6002_EN
Explanation
!
Plausibility test of ADC test between
ARM and DSP has failed
The fan is malfunctioning.
Inverter disconnected from generator
by the switch, or DC relay does not
close.
The checksum of the loaded confi g. fi le
does not match the checksum in the
EEPROM. This means that the EEPROM
data originate from a diff erent confi g.
fi le.
Action
By
 In case of
repeated occur-
rence:
Notify your
authorised elec-
trician.
 Replace defective
fan
 Notify author-
E/K
ised electrician /
KACO Service
E
E
Page 51