AIR INDUCTION SYSTEM
EAS00510
CHECKING THE AIR INDUCTION SYSTEM
1. Check:
S hoses
Loose connection ! Connect properly.
Cracks/damage ! Replace.
S pipes
Cracks/damage ! Replace.
2. Check:
S reed valve 1
S reed valve stopper
S reed valve seat
Cracks/damage ! Replace the reed valve.
3. Measure:
S reed valve bending a
Out of specification ! Replace the reed
valve.
Maximum reed valve bending
1 Surface plate
4. Check:
S air cutoff valve
Cracks/damage ! Replace.
7-15
CARB
0.4 mm