8.8.

Sequence ROI Trigger

This mode allows the user to define a preset sequence of up to 10 images, each with its own ROI,
exposure time and gain values.
Primary settings to use this mode
Exposure Mode: Timed
Trigger Mode: ON
Video Send Mode: Trigger Sequence or Command Sequence
8.8.1

Video send mode

The sequential trigger mode is selected via the Video Send Mode command and has the
following options.
Table-23 Video send mode
Mode selected
Trigger Sequence
Command Sequence
Video Send Mode
Sequence Reset
Command
Frame Start
Trigger In
Frame Active
Out
Fig. 31
8.8.2

Trigger Sequence mode basic timing

In this mode, as each trigger input is received, the image data associated with the next
index within the preset sequence is output.
GO-5000M-PGE / GO-5000C-PGE
Index selection method
Select the index by using the Frame Start trigger signal. (The
setting index can be determined by the Next Index setting.)
Select the index number to assign directly by using the
Command Sequence Index command.
"Normal"
"Trigger Sequence"
Sequence Index
Can be changed
Cannot be changed
Sequence
Index
Execute from
Index 0
Sequence Index
Stop
Behavior if Video Send Mode is set to Trigger Sequence
Sequence Index
Sequence Index
Can be changed
"Execute"
Sequen
ce
Index
Execute
from
Index 0
Sequence Index
Performing
- 45 -
"Normal"
"Trigger Sequence"
Sequence Index
Cannot be changed
Sequence
Index
Pointer
&
Repetition
Sequence
Count
Index Execute
Clear
From Index 0
Sequence Index
Sequence Index
Stop
Performing