6.4.9

Pulse Generator Clear Source

The following clear source can be selected as the pulse generator clear signal.
Table-10 Pulse generator clear source
Pulse Generator
Clear Source
item
Low
High
Frame Trigger Wait
Frame Active
Exposure Active
FVAL
LVAL
PulseGenerator0
Out
PulseGenerator1
Out
Line 5 Opt 1 In
Nand 0 Out
Nand 1 Out
Note:
The pulse generator output cannot be used as the clear input to the same pulse generator. Refer
to "6.2.7.2. Table 10 ".
GO-5000M-PGE / GO-5000C-PGE
Description
Connect Low level signal to Clear Source for the selected pulse generator.
Default setting
Connect High level signal to Clear Source for the selected pulse
generator.
Connect Frame Trigger Wait signal to Clear Source for the selected pulse
generator.
Connect Frame Active signal to Clear Source for the selected pulse
generator.
Connect Exposure Active signal to Clear Source for the selected pulse
generator.
Connect FVAL signal to Clear Source for the selected pulse generator.
Connect LVAL signal to Clear Source for the selected pulse generator.
Connect Pulse Generator 0 output to Clear Source for the selected pulse
generator.
Connect Pulse Generator 1 output to Clear Source for the selected pulse
generator.
Connect Opt 1 In signal to Clear Source for the selected pulse generator.
Connect NAND 0 output signal to Clear Source for the selected pulse
generator.
Connect NAND 1 output signal to Clear Source for the selected pulse
generator.
- 24 -