Trigger Width Mode; If The Overlap Setting Is "Off; If The Overlap Setting Is "Readout - JAI GO-5000M-PGE User Manual

5m digital progressive scan monochrome and color camera
Hide thumbs Also See for GO-5000M-PGE:
Table of Contents

Advertisement

8.6.

Trigger width mode

In this mode, the exposure time is equal to the trigger pulse width. Accordingly, longer
exposure times are supported. Additional settings determine if the trigger pulse can be accepted
during the exposure period.
Primary settings to use this mode
Exposure Mode: Trigger Width
Trigger Mode: ON
Trigger Option: OFF
8.6.1

If the overlap setting is "OFF"

Trigger
CMOS
Exposure
Exposure
Active
FVAL
8.6.2

If the overlap setting is "Readout"

Trigger
CMOS
Exposure
Exposure
Active
FVAL
t1
2L (Min)
GO-5000M-PGE / GO-5000C-PGE
t1
t2
Exposure Period
t1
t2
2L (Min)
208clk
Fig.28
t1
t2
Exposure Period
t2
208clk
Fig.29
Readout
- 43 -
t3
t3
7L to 8L
Overlap = OFF
t4
t3
t3
t4
7L to 8L
1L

Advertisement

Table of Contents
loading

This manual is also suitable for:

Go-5000c-pge

Table of Contents