Receiver Parameters; Receiver Operating Status Parameters - Cisco Prisma II Installation And Operation Manual

Prisma ii high density dual reverse receiver
Hide thumbs Also See for Prisma II:
Table of Contents

Advertisement

Appendix A
Module Parameter Descriptions

Receiver Parameters

Receiver Operating Status Parameters

Parameter
Name (LCI)
Rx 1 Nominal
Input
Rx 2 Nominal
Input
Module
Temperature
AGC 1
Attenuator
AGC 2
Attenuator
AGC 1 Opt Inp
Pwr
AGC 2 Opt Inp
Pwr
Receiver 1
Status
Receiver 2
Status
108
ICIM
Function
Abbreviation
InPwr1
Displays optical input power for Rx1
InPwr2
Displays optical input power for Rx2
ModTemp
Displays module temperature
AGC1Attn
Attenuation used for AGC1 base settings 0 dB to
AGC2Attn
Attenuation used for AGC2 base settings 0 dB to
AGC1OpIn
Optical input power used for AGC1 base
settings
AGC2OpIn
Optical input power used for AGC2 base
settings
Rx1
Indicates the status of Rx1:
Off = receiver disabled or in critical
alarm
Stby = receiver enabled with no alarms,
but in Slave mode (no RF output)
Active = receiver operating normally (RF
output active)
Rx2
Indicates the status of Rx2:
Off = receiver disabled or in critical
alarm
Stby = receiver enabled with no alarms,
but in Slave mode (no RF output)
Active = receiver operating normally (RF
output active)
Operating
Range
-20 dBm to
3.0 dBm
-20 dBm to
3.0 dBm
-40 ºC to
100 ºC
26.25 dB
26.25 dB
-18 dBm to
2.0 dBm
-18 dBm to
2.0 dBm
Off (0)
Stby (1)
Active (2)
Off (0)
Stby (1)
Active (2)
78-4015908-01 Rev F

Advertisement

Table of Contents
loading

Table of Contents