Electra Elite IPK
___________________________________________________________________________________
2.3
2.4
___________________________________________________________________________________
SPE Hardware, Installation, and Maintenance Manual
Installation
Only one SPE(M)-U( ) ETU can be installed in the system. The SPE(M)-U( )
ETU can be installed in the following slots: AP, S1 or S2. When the modem is
used the SPE(M)-U( ) ETU must be installed in the S1 or S2 slot.
Switch Settings
Switch
Setting
On
COM – D acting as a DCE (Default)
SW 1
Off
COM – D Acting as a DTE
On
COM – C acting as a DCE (Default)
SW 2
Off
COM – C Acting as a DTE
SW 3
NA
Reset the SPE(M)-U( ) ETU
On
Not Used
SW 4-1
Off
Not Used (Default)
On
Restores Card to Factory Defaults
SW 4-2
Off
Save Settings (Default)
On
Not Used
SW 4-3
Off
Not Used (Default)
On
Not Used
SW 4-4
Off
Not Used (Default)
On
Not Used
SW 4-5
Off
Not Used (Default)
On
Not Used
SW 4-6
Off
Not Used (Default)
On
Enables Debug through COM 1 of the KSU
SW 4-7
Off
Debug is disabled through COM 1 of KSU (Default)
On
MIFM Mode Only ( Emulates MIFM; SPE features are
disabled)
SW 4-8
Off
SPE Mode (Default)
Table 1-2 Switch Settings
Description
Document Revision 1
1 - 5