D. MODEL #CSK-31 ONLY: FAN INSTALLATION INSTRUCTIONS
This fireplace insert comes complete with a fan and thermostatic control switch already installed. A speed control,
receptacle and 8 ft. fan cord have been installed, wired and mounted in a removable electrical box panel on the right side of
the fireplace. If wiring to the pre-installed electrical box is desired, the wiring should be run prior to permanently setting the
insert in place and connecting the vent system. A direct wire connection to the electrical box provided must be performed by
a qualified electrician.
NOTE:
If this fireplace insert is being installed in the minimum opening dimensions, the wiring may need to be completed
after the fireplace insert is set in place.
The fan is equipped with a three-prong (grounding) plug attached to the end of the fan electrical cord for protection against
shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not remove the grounding
prong from the plug. Do not allow any excess fan cord to touch the fireplace.
NOTE:
Code approved line voltage wiring 14 gauge or better must be used when wiring this assembly. Refer to your local
electrical codes for specific requirements in your area.
WARNING:
This appliance is equipped with a three-prong (grounding) plug for protection against shock hazard and should
be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding
prong from this plug.
DIRECT WIRE INSTALLATION:
NOTE: The cord must be removed and wiring disassembled.
Insert 115 V wiring (with ground) through the romex connector and wire
to the speed control / receptacle assembly, matching the black, white &
green (ground) wires to the corresponding wires on the speed control /
receptacle assembly.
Figure D-1
DIRECT WIRE INSTALLATION:
1.
Loosen the screw securing the removable access panel (with electrical box & romex connector installed) from inside the right
side of the fireplace. Remove the panel.
2.
Remove the (2) screws securing the speed control / receptacle assembly to expose the wiring.
3.
Remove existing cord and insert 115V wiring (with ground) through the romex connector and wire to the speed control /
receptacle assembly matching the black (hot) white (neutral) and green (ground) wire to the corresponding wire on the speed
control / receptacle assembly. NOTE: The (3) wire nuts obtained when removing the existing cord, may be used for this
purpose.
4.
Secure the speed control / receptacle assembly into the electrical box with the (2) screws provided.
This appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Codes, CSA C22.1.