PROBLEM
4.
Burner won't light.
5.
Burner won't stay lit.
WIRING DIAGRAM
Model CSK-31-RF
Figure Q-2
CAUSE
Pilot not lit.
Regulator valve not turned "ON".
Rocker switch not turned "ON". (Model CSK-31).
Rocker switch wires not connected. (Model CSK-31).
Generator wires loose at regulator terminals
Generator wire grounded out
due to pinching of wires.
Generator is not producing enough
millivolts to operate burner.
Wall switch, remote control or thermostat not
connected properly or turned to wrong setting. See
Figures M-1 & M-2, page #18. (Model CSK-31).
Generator wires loose on
valve terminals.
Generator wire grounded out
due to pinched wires.
Generator is not producing enough
millivolts to sustain burner operation.
Refractory panels not positioned
against firebox.
Page 29
SOLUTION
Relight pilot.
Turn valve to "ON"
Depress switch.
Check wiring diagram Figure Q-1
to ensure that all wires are secure.
Reposition wire an tighten screws. See
Figures Q-1 & Q-2 for wiring instructions.
Nuts securing millivolt board may need
loosening to remove pinched wire.
Replace generator.
Connect properly or disconnect
and use ON/OFF switch only.
Reposition wires and tighten screws
See Figures Q-1 & Q-2 for wiring
instructions.
Nuts securing millivolt board may need
loosening to remove pinched wire.
Check millivolt reading, replace
generator if necessary.
Secure refractory panels with
high-temp sealant.