kozy heat CSK-29-MV Operation Manual
kozy heat CSK-29-MV Operation Manual

kozy heat CSK-29-MV Operation Manual

Direct vent gas fireplace insert
Hide thumbs Also See for CSK-29-MV:

Advertisement

HUSSONG MANUFACTURING CO., INC.
CHASKA 2 9 M V
Model #CSK-29-MV
Direct Vent Gas Fireplace Insert
English and French installation manuals are available through your
local dealer. Visit our website www.kozyheat.com.
Les manuels d'installation en français et en anglais sont disponibles
chez votre détaillant local. Visitez www.kozyheat.com .
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
ͷ Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
ͷ WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
ͷ Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
Hussong Mfg. Co., Inc. • CSK-29-MV
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATION AND
OPERATION MANUAL
This
appliance
an
aftermarket,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
DANGER
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed for the protection
of children and other at-risk individuals.
Report No: F18-440 • Rev. 6, January 2019
may
be
installed
permanently
located,
HOT GLASS WILL
CAUSE BURNS
DO NOT TOUCH GLASS
UNTIL COOLED
NEVER ALLOW CHILDREN
TO TOUCH GLASS
in

Advertisement

Table of Contents
loading

Summary of Contents for kozy heat CSK-29-MV

  • Page 1 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. Hussong Mfg. Co., Inc. • CSK-29-MV Report No: F18-440 • Rev. 6, January 2019...
  • Page 3 We pride ourselves in being dedicated not only to functionality and reliability, but also customer safety. We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace.
  • Page 5: Table Of Contents

    6.5 Connect Vent Pipe to Vent Adapter ............17 15.0 REPLACEMENT PARTS LIST..........36 6.6 Place and Secure Appliance ..............17 LIMITED LIFETIME WARRANTY ............ 37 6.7 Outdoor Covered Fireplace Installation ..........18 #CSK-29-MV R.6 January 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces TABLE OF CONTENTS...
  • Page 7: Introduction

    Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. #CSK-29-MV R.6 January 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 7...
  • Page 8: Specifications

    When the appliance is installed at elevations above 4,500 ft (1,372 m), the certified high altitude rating shall be reduced at the rate of 4% for each additional 1,000 ft (305 m). 8 SPECIFICATIONS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CSK-29-MV R.6 January 2019...
  • Page 9: Appliance Dimensions

    ⁄ ” 2” (46mm) (51mm) ELECTRICAL GAS LINE ACCESS HOLE ½ ⁄ ⁄ ” ” ” (750mm) (214mm) (183mm) LEFT FRONT RIGHT Figure 2.1, Appliance Dimensions #CSK-29-MV R.6 January 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces SPECIFICATIONS 9...
  • Page 10: Part Assembly Overview

    Table 2.1, Field-Assembled Parts Fireplace insert Control module Glass frame assembly Fan kit Ember media tray and log rack Co-linear vent adapter Control board with burner assembly 10 SPECIFICATIONS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CSK-29-MV R.6 January 2019...
  • Page 11: Safety Barrier Dimensions

    (513mm) (513mm) (513mm) CK29-PSF CK29-RSF CK29A-MSF ¾ ¾ ” ” 31” (807mm) (807mm) (786mm) ¼ ¼ ” ” ⁄ ” (515mm) (515mm) (478mm) CK29A-SF CK29A-PSF CK29A-FPDSF2 #CSK-29-MV R.6 January 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces SPECIFICATIONS 11...
  • Page 12: Existing Fireplace Requirements

    This is the total length of the co-linear flexible aluminum pipe HAS BEEN MODIFIED’ label at bottom of existing firebox so it will required for your installation. If using Kozy Heat #816, cut to be visible if this gas fireplace insert is removed.
  • Page 13: Termination Location

    Approved vent caps require 12 in (305mm) clearance to intersecting walls, overhangs or eaves as verified by test. APPROVED VENT CAP MINIMUM 12” (305mm) CLEARANCE Figure 4.1, Vent Cap Clearance #CSK-29-MV R.6 January 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces TERMINATION LOCATION...
  • Page 14: Installation Preparation

    Authority Having Jurisdiction. Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CSK-29-MV R.6 January 2019 INSTALLATION PREPARATION...
  • Page 15: Installation

    Complete vent system installation by following the instructions COMBUSTION AIR EXHAUST COLLAR (RIGHT) outlined in Sections 6.3 through 6.6. INTAKE COLLAR (LEFT) VENT ADAPTER (TOP VIEW) Figure 6.1, #816-CAP #CSK-29-MV R.6 January 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INSTALLATION...
  • Page 16: Remove Vent Adapter

    OPTIONAL Kozy Heat #816-CAP: Secure termination cap to existing chimney with 2 in (50 mm) self-tapping screws and anchor straps (not provided) through the pilot holes, located on the sides of the termination cap.
  • Page 17: Connect Vent Pipe To Vent Adapter

    Figure 6.5, Aligned Insert SECURE WITH (2) SCREWS PULL ROD SHEET METAL SCREWS (3 TOTAL) SEALANT SEALANT Figure 6.6, Seated Vent Adapter Figure 6.4, Vent Pipe Connection to Vent Adapter #CSK-29-MV R.6 January 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INSTALLATION...
  • Page 18: Outdoor Covered Fireplace Installation

    EXAMPLE: If roo ine (B) is 10 ft above the base of replace, the overhang (A) must be 5 ft or greater. The width of the overhang to EACH side of the replace (C) must be 5 ft or greater. Figure 6.7, Outdoor Covered Fireplace Installation Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CSK-29-MV R.6 January 2019 INSTALLATION...
  • Page 19: Gas Line Connection

    Table 7.1, Inlet Gas Supply Pressures Fuel Minimum Pressure Maximum Pressure Natural Gas 5” WC (1.25 kPa) 10.5” WC (2.62 kPa) Propane 11” WC (2.74 kPa) 13” WC (3.24 kPa) #CSK-29-MV R.6 January 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces GAS LINE CONNECTION...
  • Page 20: Facing And Finishing

    COMBUSTIBLE MATERIAL 6” (152mm) CLEARANCE TO ADJACENT SIDEWALL CEILING COMBUSTIBLE MANTEL 11” (305mm) 9” (254mm) 16” 55” (407mm) (1.40m) ¼ ” (895mm) ¼ ” (946mm) Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CSK-29-MV R.6 January 2019 FACING AND FINISHING...
  • Page 21: Ck29-Lmk Low Mantel Kit

    UNDER THE MOUNTING TABS AS SHOWN REPLACE (2) SCREWS THROUGH THE HOLES IN THE MOUNTING TAB AND HEAT DEFLECTOR GASKET MUST BE IN CONTACT WITH SHROUD #CSK-29-MV R.6 January 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING...
  • Page 22 THESE LOWER MANTEL CLEARANCES ARE ALLOWED CEILING 9” (229mm) 55” 6” (152mm) (1.40m) 11” 14” (279mm) (356mm) CK29-PSF, CK29-RSF WITH LOW CLEARANCE MANTEL KIT INSTALLED Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CSK-29-MV R.6 January 2019 FACING AND FINISHING...
  • Page 23: Shroud Installation

    Reinstall all components previously removed. UPPER LOUVER LOWER LOUVER Figure 8.1, Upper Louver and Lower Louver Removal MOUNTING NUTS (2 EACH SIDE) Figure 8.2, Mounting Nuts Location #CSK-29-MV R.6 January 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING...
  • Page 24: Gas Fireplace Insert Setup

    Pull the spring-loaded latches out and up to secure the bottom of glass to the bottom of the fireplace. Reinstall safety barrier. TABS SPRING-LOADED LATCHES Figure 9.1, Glass Frame Assembly Installation and Removal Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CSK-29-MV R.6 January 2019 GAS FIREPLACE INSERT SETUP...
  • Page 25: Ck29-500 Log Set Installation

    Position the ember panel in front of the burner as shown. Align the holes in base logs CK29-1, CK29-2, CK29-3, and CK29-4 Figure 9.2, Installation of CK29-500 #CSK-29-MV R.6 January 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces GAS FIREPLACE INSERT SETUP...
  • Page 26: Control Board Removal And Installation

    Figure 9.3, Control Board Removal and Installation 10. Turn the manual valve counter clockwise to the ON position. 11. Verify proper log placement, operation of fireplace, and any electrical components. Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CSK-29-MV R.6 January 2019 GAS FIREPLACE INSERT SETUP...
  • Page 27: Electrical Information

    Follow instructions included with assembly. • If an optional component is to be used, run low-voltage wires from gas valve to the location of component. #CSK-29-MV R.6 January 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ELECTRICAL INFORMATION...
  • Page 28 TH and TP-TH on gas valve Figure 10.2, Millivolt Gas Valve Wiring Schematic with Thermostat or Wall Switch Wiring Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CSK-29-MV R.6 January 2019 ELECTRICAL INFORMATION...
  • Page 29: Operating Instructions

    Push in gas control knob slightly and turn clockwise performed. “OFF”. Open the control compartment access panel to access gas Set the control compartment access panel back into position. #CSK-29-MV R.6 January 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces OPERATING INSTRUCTIONS...
  • Page 30: Adjustment

    Disconnect hose and tighten the inlet (IN) pressure tap by (A) INLET PRESSURE TAP (B) MANIFOLD PRESSURE TAP Figure 12.1, Pressure Check Taps Locations (Millivolt Gas Valve) Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CSK-29-MV R.6 January 2019 ADJUSTMENT...
  • Page 31: Burner Flame Adjustments

    Loosen screw on venturi and adjust as necessary. Re-tighten screw. Reinstall all components previously removed. SHORT, BLUE FLAMES BURNER VENTURI LIFTING (GHOSTING) FLAMES Figure 12.3, Flame Characteristics Figure 12.2, Burner Venturi Location #CSK-29-MV R.6 January 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ADJUSTMENT...
  • Page 32: Troubleshooting

    Install pilot shield. Pilot safety dropout Pilot flame is too high or too low. Clean pilot hood and adjust pilot flame for maximum flame impingement on thermopile. Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CSK-29-MV R.6 January 2019 TROUBLESHOOTING...
  • Page 33 Blockage or leakage of the vent Check the vent pipe for leaks, and the vent cap for debris. Repair vent system pipe or remove debris from vent cap if necessary. #CSK-29-MV R.6 January 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces TROUBLESHOOTING...
  • Page 34: Maintenance

    Qualified Service Person Performed by: Annually Frequency: Action: • Examination of the vent system is required. • The flow of combustion and ventilation air must not be obstructed. Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CSK-29-MV R.6 January 2019 MAINTENANCE...
  • Page 35: Burner And Pilot System

    Test and measure the flame failure response time of the flame safety system. It must de-energize the safety shutoff in no more than (30) seconds. BURNER ORIFICE BURNER PORTS Figure 14.1, Burner System #CSK-29-MV R.6 January 2019 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces MAINTENANCE...
  • Page 36: Replacement Parts List

    Rock Wool Embers 900-REMB Custom shroud CK29-CUS Custom arched shroud CK29-ACUS #CSK-29-MV Hussong Manufacturing Co., Inc. P.O. Box 577 204 Industrial Park Drive Lakefield, MN 56150-0577 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #CSK-29-MV R.6 January 2019 REPLACEMENT PARTS LIST...
  • Page 37: Limited Lifetime Warranty

    • All parts and material except the items listed in the 30 day Kozy Heat gas appliance from the date of purchase to the original warranty and any exclusions or limitations that may apply. purchaser, that it is free of defects in materials and workmanship at *Hussong Mfg.

This manual is also suitable for:

Chaska 29 mv