MODEL #CSK-31-RF ONLY: FAN INSTALLATION INSTRUCTIONS
I
NSTALLATION OF THIS FAN WIRING SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER
IMPORTANT:
A fan assembly is pre-installed and wired to the RF gas valve in the CSK31-RF models.
A receptacle and 8 ft. fan cord have been installed, wired and mounted in a removable electrical box panel on the right side of
the fireplace. If direct wiring to the pre-installed electrical box is desired, the wiring should be completed prior to permanently
setting the insert in place and connecting the vent system. Code approved line voltage wiring 14 gauge or better must be
used when wiring this assembly. Refer to your local electrical codes for specific requirements in your area. A direct wire
connection to the electrical box provided must be performed by a qualified electrician.
NOTE:
If this fireplace insert is being installed in the minimum opening dimensions, the wiring may need to be completed
after the fireplace insert is set in place.
The fan is equipped with a three-prong (grounding) plug attached to the end of the fan electrical cord for protection against
shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not remove the grounding
prong from the plug. Do not allow any excess fan cord to touch the fireplace.
WARNING: This appliance is equipped with a three-prong (grounding) plug for protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from
this plug.
Figure D-2
DIRECT WIRE INSTALLATION:
NOTE: The cord must be removed and wiring disassembled.
Insert 115 V wiring (with ground) through the romex connector
and wire to the receptacle matching the black, white & green
(ground) wires to the corresponding wires on the receptacle.
DIRECT WIRE INSTALLATION:
1.
Loosen the screw securing the removable access panel (with electrical box & romex connector installed) from inside the right
side of the fireplace. Remove the panel.
2.
Remove the (2) screws securing the receptacle assembly to expose the wiring.
3.
Remove existing cord and insert 115V wiring (with ground) through the romex connector and wire to the receptacle, matching
the black (hot) white (neutral) and green (ground) wire to the corresponding wire on the receptacle. NOTE: The (3) wire nuts
obtained when removing the existing cord may be used for this purpose.
4.
Secure the receptacle assembly into the electrical box with the (2) screws provided.
This appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Codes, CSA C22.1.