3 TIG WELDING
Voltage Reducing Device (VRD)
The VRD function ensures that the open-circuit voltage does not exceed 35 V
when welding is not being carried out. This is indicated by a lit VRD LED.
The VRD function is blocked when the system senses that welding has started.
If the VRD function is activated and the open-circuit voltage exceeds the 35 V
limit, this is indicated by an error message (16) appearing in the display and
welding cannot be started whilst the error message is displayed.
Contact an authorised ESAB service technician to activate the function.
3.3

Hidden TIG functions

There are hidden functions in the control panel.
Control panel A32: To access the hidden functions, press the method button
Control panels A33 and A34: To access the hidden functions, press
display shows a letter and a value. Select the preferred function by pressing the appropriate
button. The knob is used to change the value of the selected function.
Control panel A32: To leave hidden functions, press the method button
Control panels A33 and A34: To leave hidden functions, press
Control panels A32, A33 and A34
Function
h = Hot Wire TIG, On/Off
U = Hot Wire TIG, Arc switch-off voltage
S = Hot Wire TIG, Automatic start
0460 449 274
Settings
0 = OFF, 1 = ON
2 - 30 V
0 = Automatic start off, 1 = Automatic start on
- 9 -
.
for 5 seconds. The
for 5 seconds.
for 5 seconds.