ymptom / Recommendation
PIR Movement Detector not detecting a
person's movement
1. Ensure the battery clip is securely connected.
2. Ensure the 'House Code' is correctly set to the
same code as all other system devices.
3. Sensitivity set too LOW - reset to HIGH sensitivity,
(i.e. DIP 5 of SW3 ON).
4. Ensure the DIP switches 1, 2 and 3 of SW3 are
correctly set (i.e. 1 = ON, 2 = ON and 3 = OFF).
5. Ensure the detector is mounted the correct way up,
(i.e. with detection window at the bottom).
6. Ensure the detector is mounted at the correct
height, (i.e. 2 - 2.5 metres).
7.
llow up to 3 minutes for the detector to stabilize
and become fully operational. Leave the area for
this period.
8. Ensure the detector is within effective radio range
of the Siren and is not mounted close to metal
objects which may interfere with the radio
transmission.
PIR Movement Detector LED flashes on
detection of movement, (device in Normal
Operation Mode)
1. Ensure the detector is configured for normal
operation (i.e. DIP switch 4 of SW3 is OFF).
2. Low battery - Replace battery.
Magnetic
ontact Detector not working
1. Ensure the Magnet is correctly positioned in
relation to Detector and that the gap between
Magnet and Detector is less than 10mm.
2. Ensure the batteries are fitted with correct polarity.
3. Ensure the battery holder connections are making
good contact with the batteries and PCB
(Circuit board).
4. Ensure the 'House Code' is correctly set to the
same code as all other system devices.
5. Ensure the DIP switches 9, 10 and 11 are correctly
set (i.e. 9 = ON, 10 = ON and 11 = OFF).
ymptom / Recommendation
6. If there is no additional wired Magnetic Contact
connected ensure the jumper link is fitted.
7. If an additional wired Magnetic Contact is
connected:
a. Ensure the jumper link is removed.
b. Check that both contacts are closed.
c. Check that additional contact is correctly wired.
Note: If an additional wired contact is used, the
doors/windows connected to both contact
detectors must be closed when the system is
armed (otherwise neither door/window will
be protected).
8. Ensure the detector is within effective radio range
of the Siren and is not mounted close to metal
objects which may interfere with the radio
transmission.
Magnetic
ontact Detector false alarming
1. Ensure the Magnet is correctly positioned in
relation to Detector.
2. Ensure the gap between Magnet and Detector is
less than 10mm.
3. Tamper switch below battery cover not depressed
- check battery cover is fitted correctly and that
fixing lugs are not broken.
LED on Magnetic
illuminating when door or window is opened
1. Low battery - Replace batteries.