Displaying Syslog messages for temperature
MAC 1 Temperature Readings:
CPU Temperature Readings:
Boot Prom MAC : 0000.0000.0720
Management MAC: 0000.0000.0720
Syntax: show chassis
Displaying Syslog messages for temperature
The software sends a Syslog message and an SNMP trap if the temperature crosses the warning or
shutdown thresholds. The following methods describe how to view the system log on the device. If you
have configured the device to use a Syslog server or SNMP trap receiver, see the documentation for
the server or receiver.
To display the system log, enter the show log command at any CLI level.
device# show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 8 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Static Log Buffer:
Dynamic Log Buffer (50 entries):
at 0 days 0 hours 2 minutes 0 seconds, level alert
Temperature 48.0 C degrees, warning level 45.0 C degrees, shutdown level
55.0 C degrees
at 0 days 0 hours 1 minutes 0 seconds, level alert
Temperature 40.0 C degrees, warning level 35.0 C degrees, shutdown level
45.0 C degrees
Changing temperature warning and shutdown levels
The default warning temperatures and the default shutdown temperatures for the device are:
- Warning temperature is 85 Deg-C (measured on mainboard)
- Shutdown temperature is 90 Deg-C (measured on mainboard)
NOTE
These temperatures reflect the temperature of the board inside the device.
To change the temperature at which the device sends a warning, enter a command similar to the
following at the Privileged EXEC level of the CLI:
device# temperature warning 1 85
Syntax: temperature warning stack-id value
The stack-id can be 1 - 8.
The value can be 0 - 125
device# temperature
temperature
device# temperature warning
warning
78
2 <- 3 @ 62 deg-C
Current temperature : 58.5 deg-C
Current temperature : 52.0 deg-C
Warning level.......: 75.0 deg-C
Shutdown level......: 90.0 deg-C
temperature sensor commands
Temperature at which the module sends a warning
Brocade FCX Series Hardware Installation Guide
53-1002977-01