88
FRU Pwr Denied
89
FRU MngtPwr Fail
90
FRU0 Agent
91
FRU1 Agent
92
FRU2 Agent
93
FRU3 Agent
94
FRU4 Agent
FRU Power Denial Detection
Sensor type = CDh OEM (Kontron FRU Power denied)
Discrete
Event Reading type code = 03h Digital Discrete offset 0,1 are used
-see OEM table, Sensor type code CDh (Kontron OEM FRU Power
Denied) for sensor definition
FRU Management Power Fail
Sensor type = D2h OEM (Kontron FRU Management Power Fail)
Event Reading type code = 03h Digital Discrete offset 0,1 are used
Discrete
-see OEM table, Sensor type code D2h (Kontron OEM FRU
Management Power Fail) for sensor definition
FRU Information Agent - FRU0 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Event Reading type code = 0Ah Generic Discrete
Discrete
Only offset 6,8 are used
See OEM table, Sensor type code C5h (Kontron OEM FRU
Information Agent) for sensor definition
FRU Information Agent - FRU1 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Discrete
Event Reading type code = 0Ah Generic Discrete
Only offset 6,8 are used -see OEM table, Sensor type code C5h
(Kontron OEM FRU Information Agent) for sensor definition
FRU Information Agent - FRU2 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Discrete
Event Reading type code = 0Ah Generic Discrete
Only offset 6,8 are used -see OEM table, Sensor type code C5h
(Kontron OEM FRU Information Agent) for sensor definition
FRU Information Agent - FRU3 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Discrete
Event Reading type code = 0Ah Generic Discrete
Only offset 6,8 are used -see OEM table, Sensor type code C5h
(Kontron OEM FRU Information Agent) for sensor definition
FRU Information Agent - FRU4 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Discrete
Event Reading type code = 0Ah Generic Discrete
Only offset 6,8 are used -see OEM table, Sensor type code C5h
(Kontron OEM FRU Information Agent) for sensor definition
54
AT8060