52
Power State
53
Power Good
54
Power Good Event
55
Board Reset
56
POST Value
57
Memory Err
Board Power State
Sensor type = D0h Kontron OEM Power State Sensor
Discrete
Event Reading type code = 6Fh Sensor specific
See OEM sensor table, Sensor type code D1h for sensor definition
Actual power good status
Sensor type = 08h Power Supply
Discrete
Event Reading type code = 77h OEM
See OEM sensor table, Event/Reading type code 77h for sensor
definition
Power good status event that occur since the last power on or
reset
Sensor type = 08h Power Supply
Discrete
Event Reading type code = 77h OEM
See OEM sensor table, Event/Reading type code 77h for sensor
definition
Board reset type and sources
Sensor type = CFh OEM (Kontron Reset Sensor)
Discrete
Event Reading type code = 03h Digital Discrete
Only offset 0,1 are used
See OEM sensor table, Sensor type code CFh for sensor definition
Show current postcode value. No event generated by this sensor
Sensor type = C6h OEM (Kontron POST value sensor)
Discrete
Event Reading type code = 6Fh Sensor specific
Only offset 0 to 7 and 14 are used
See OEM sensor table, Sensor type code C6h for sensor definition
Memory Error
Sensor type = 0Ch Memory
Event Reading type code = 6Fh Sensor specific
Discrete
Only offset 0,1,7 are used
See IPMI v2.0 table 42-3, Sensor type code 0Ch for sensor
definition
48
AT8060
www.kontron.com