Kontron AT8060 User Manual page 116

Single width atca compliant processor blade
Hide thumbs Also See for AT8060:
Table of Contents

Advertisement

5.1.6.2
Power Limit options sub-menu
Feature
Option
Power Limit options
Activated,
Power Limit
Deactivated
Power Limit Value
No action, Hard
Power Off System
Exception Action
and log event to SEL,
Log event to SEL
only
Correction Time Limit
Statistics Sampling period
Description
Subtitle
Numeric
Numeric
Numeric
101
Software Setup
Help text
Activate/Deactivate
Power Limit option
Set the Power Limit
threshold value
Exception action taken if
the Power Limit is
exceeded and cannot be
controlled within the
Correction time limit
Maximum time in
miliseconds taken to
limit the power after the
platform power has
reached the power limit
before the Exception
Action will be taken
Statistics sampling
period in seconds