CRANKCASE
EAS00386

DISASSEMBLING THE CRANKCASE

NOTE:
_
Loosen the generator shaft bolt before remov-
ing the generator rotor.
1. Remove:
• generator shaft bolt 1
NOTE:
_
While the holding the generator rotor 2 with
the primary sheave holder 3, loosen the gen-
erator shaft bolt.
Primary sheave holder
YS-01880-A
2. Remove:
• crankcase bolts
• holder
NOTE:
_
• Loosen each bolt 1/4 of a turn at a time, in
stages and in a crisscross pattern. After all of
the bolts are fully loosened, remove them.
• Loosen the bolts in decreasing numerical
order (refer to the numbers in the illustra-
tion).
• The numbers embossed on the crankcase
indicate the crankcase tightening sequence.
È Right crankcase
É Left crankcase
M8 × 100 mm bolts: 1, 2
M8 × 80 mm bolt: 3
M6 × 105 mm bolt: K
M6 × 85 mm bolts: 9, C
M6 × 75 mm bolts: D, E
M6 × 60 mm bolts: 4 ~ 7
M6 × 40 mm bolts: 8, 0 ~ B, F ~ J
5 - 96