Smart Throttle; Air Conditioning Operation - Kipor SINEMASTER IG6000 Owner's Manual

Digital generator
Hide thumbs Also See for SINEMASTER IG6000:
Table of Contents

Advertisement

5.5 Smart Throttle

Engine speed is kept at idle automatically when the electrical load is disconnected and it returns to the
proper speed when the load is reconnected.
This position is recommended to minimize fuel
consumption while in operation
Smart throttle
Smart Throttle Switch
NOTE
■When high electrical load appliances are connected simultaneously. turn the smart throttle switch to
the OFF position to reduce voltage changes.
■Smart throttle system does not operate sufficiently if the electrical appliance requires the much electric
power.

5.6 Air Conditioning Operation

For best results, the SMART throttle switch should be in the off position. Bring the generator to a
normal operating temperature before applying the air conditioning load. Always allow a 2 minute wait
period when manually cycling an air conditioner off and on. A longer wait period may be required
under unusually hot weather conditions. Additionally, all other loads should be turned off until the air
conditioner has started and is performing normally. It is also important to follow the air conditioner
manufacturer's instructions for starting and restarting for proper operation. Some air conditioner
manufacturers offer a start capacitor as an extra cost option. The lack of a start capacitor can cause
the air conditioner to draw too high a starting current and overload the generator. Contact your air
conditioner dealer if you consistently have problems starting your air conditioner with the generator.
This generator is not recommended for air conditioners exceeding 13,500 BTUs.
-14-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinemaster ig6000h

Table of Contents