Low Oil Alarm System - Kipor SINEMASTER IG6000 Owner's Manual

Digital generator
Hide thumbs Also See for SINEMASTER IG6000:
Table of Contents

Advertisement

2. Start the generator.
■ The DC receptacle may be used while the AC power is in use.
■ The DC receptacle is protected from an overload with a fuse. If the DC circuit is overloaded, the 5
amp fuse will blow and power to the DC receptacle will cease. The red light on the DC panel will
illuminate. The fuse is located in the receptacle and is accessed by snapping open the fuse panel.
Replace the fuse with one of the same capacity. Using a higher rated fuse may cause damage to the
generator alternator.

5.8 Low oil alarm system

The low oil alarm system is designed to prevent engine damage caused by an insufficient amount of oil
in the crankcase. Before the oil level in the crankcase falls below a safe limit, the low oil alarm
system will automatically shut down the engine (the engine switch will remain in the ON position).
If the low oil alarm system shuts down the engine the red low oil alarm indictor light will come on when
you operate the starter, and the engine will not run. If this occurs, search for any oil leaks. Add engine
oil to resume normal operation.
■ Keep out of reach of children.
The DC output is to be used to charge batteries only. Serious
damage to the stator windings can occur if connected to a DC motor
or transformer.
Open
-16-
险丝
Fuse
直 流插座
DC receptacle