Spark Plug Service - Kipor SINEMASTER IG6000 Owner's Manual

Digital generator
Hide thumbs Also See for SINEMASTER IG6000:
Table of Contents

Advertisement

1. Open the left side maintenance door.
2. Unsnap the clips and remove the air cleaner cover.
3. Remove the air cleaner element and examine for dirt or damage. Replace it with a new one if
necessary. Do not attempt to clean the paper element.
4. Reinstall the air cleaner cover.
5. Close and latch the service door.
空滤底座
Air cleaner base
滤芯
Air Cleaner element
空滤盖
Air cleaner cover

7.4 Spark plug service

To ensure proper engine operation, the spark plug must be properly gapped and free of deposits.
1. Open the left side maintenance cover.
2. Remove the spark plug cap.
Spark plug wrench
Spark plug lever
3. Clean any dirt from around the spark plug base.
4. Use the wrench to remove the spark plug.
5. Visually inspect the spark plug. Discard it if the porcelain insulator is cracked or chipped. Clean the
spark plug with a wire brush if it is to be reused.
6. Measure the plug gap with a feeler gauge. The gap should be 0.028-0.031 in (0.7-0.8 mm).Correct