SCANNER UNIT

3.4.2 LENS BLOCK

CAUTION
1) DO NOT disassemble the lens block. The lens block is fine-adjusted
before shipment.
2) DO NOT touch the screws on the CCD. The CCD is fine-adjusted before
shipment.
1. Exposure glass (
2. Front left cover, fax operation panel,
operation panel (
3. Release the cable from the four
clamps [A].
4.
Lens block [B] (
NOTE: 1) Do not loosen the paint-
locked screws holding the
lens unit in place.
2) After installing a new lens
block, perform copy
adjustments (

3.4.3 EXPOSURE LAMP, LAMP STABILIZER BOARD

NOTE: DO NOT fold the exposure cable on the exposure lamp.
1. Exposure glass (
2. Front left cover, fax operation panel
(
3.3.5)
3. Slide the first scanner to a position
where the lamp and scanner are clear
of the metal lids.
4. Disconnect the lamp connector [A].
5. Remove either or both of the following:
• Exposure lamp [B] (
• Lamp stabilizer board [D] (
1 flat cable)
B129 Series/B044 Series
CÓPIA NÃO CONTROLADA
3.4.1)
3.3.5)
× 4, 1 flat cable)
3.14).
3.4.1)
x 1 [C])
x 2 [E],
3-10
CÓPIA NÃO CONTROLADA
[A]
[E]
[D]
[A]
[C]
Rev. 11/15/2004
[B]
B130R946.WMF
[B]
B130R947.WMF
SM