SERVICE MENU

3.2 SERVICE MENU

3.2.1 BIT SWITCH SETTINGS

The bit switches are not used at the moment.

3.2.2 NV RAM CLEAR

!
CAUTION
Print the service summary report, controller configuration page, and NIB
configuration page before resetting the NV RAM(s).
1. Enter the printer SP mode, and select "1. Service Menu".
2. Select the appropriate menu, and then press "OK".
B: NV RAM Clear 1
C: NV RAM Clear 2
D: NV RAM Clear 3
3. Ensure that you have printed the appropriate configuration sheet, then press
"OK".
B: Service Summary Sheet
C: Service Summary sheet and Controller Configuration Sheet
D: NIB Configuration Sheet
4. Press "OK" to execute. Or press "Cancel" to exit.

3.1.3 COUNTER CLEAR

1. Enter the printer SP mode, and select "1. Service Menu".
2. Select "E. Counter Clear", then press "OK".
3. Press "OK" to execute. Or press "Cancel" to exit.

3.1.4 DIAGNOSTIC ERROR

This displays the latest 8 error codes that were found during the power-on self-test.
Refer to section 2.1 for details of the error codes.
1. Enter the printer SP mode, and select "1. Service Menu".
2. Select "F. Diagnostic Error ", then press "OK".
3. Look through the error codes by using the right and left cursor keys.
4. Press "Cancel" to exit.
B441
CÓPIA NÃO CONTROLADA
3-2
CÓPIA NÃO CONTROLADA
SM