How To Clear The Pm Counter - Gestetner B130 Service Manual

Table of Contents

Advertisement

HOW TO CLEAR THE PM COUNTER

ADF
Separation roller
Pick-up roller
Feed roller
White plate
DF exposure glass
Rollers R0, R1, R2
PAPER TRAY UNIT
Paper feed roller
Bottom-plate pad
Friction pad
2.2 HOW TO CLEAR THE PM COUNTER
Reset the PM counter after completing all maintenance activities.
1. Activate the SP mode.
2. Select SP7-804-001.
3. Press the EXECUTE key [A]. The
message "Completed" is displayed
when the program ends normally. An
error message is displayed if the
program ends abnormally.
4. Press the
(cancel) key [B] to end the program.
B129 Series/B044 Series
CÓPIA NÃO CONTROLADA
Every 90k
R
R
R
Every 120k
R
R
2-2
CÓPIA NÃO CONTROLADA
AN
C
Water or alcohol
C
Water or alcohol
C
Water or alcohol
C
Water or alcohol
C
Water
C
Water or alcohol
AN
C
Dry cloth
7.804.001 Reset-PM Count
EXECUTE
[A]
NOTE
NOTE
B130P901.WMF
[B]
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B129B045B168B169B046B044

Table of Contents